全 8240 件が検索されました。(3861 - 3880件を表示)

  • マニュアル

    ...8 Macro Functions *MEASUREDISPG Rem Get the GetUnitData GetUnitData GetUnitData GetUnitData GetUnitData measurement result. 5, 5, X# 5, 6, Y# 5, 7, R# 5, 8, R_MAX# 5, 9, R_MIN# Rem Determine the width. ...

  • マニュアル

    ... other devices in the circuit causes the diode to generate an abnormal amount of heat, which may lead to damage. This damage can occur easily when a surge current flows through the diode due to it being connected to an inductive load of 10 ...

  • マニュアル

    ... other devices in the circuit causes the diode to generate an abnormal amount of heat, which may lead to damage. This damage can occur easily when a surge current flows through the diode due to it being connected to an inductive load of 10 ...

  • マニュアル

    ... reactance current limiting elements types can be used. Recommended values for the SSR load current and protective resistance during single-phase motor forward/reverse operation Single-phase motor forward/reverse operation Motor Load power supply 100 V single-phase motor 25 ...

  • マニュアル

    ...Supply voltage Power consumption Ambient operating temperature Ambient operating humidity Ambient storage temperature Ambient storage humidity Insulation resistance Dielectric strength Vibration resistance V780-HMD68-ETN- V780-HMD68-ETN--S 250 × 250 × 70 mm (...

  • マニュアル

    ... in wiring? • The recommended power supply for V430 is the S8VS-24 (manufactured by OMRON) or S8VK-G-24 (manufactured by OMRON). Ground • Check wiring again before turning on the V430 reader. Other • Use only the cables (V430-...

  • マニュアル

    ... Manual (Z396) 1 Data Management and Clock Functions 1-2-6 Related System-defined Variables Variable names Meaning Function System Time This variable contains the Communication Control Unit’s internal clock data. Data type DATE_AND_TIME R/...

  • マニュアル

    ... of maximum load current for test output of this safety I/O terminal. Residual voltage at test output ON of this safety I/O terminal. Leakage current at test output OFF of this safety I/O terminal. External dimensions of this safety I/O terminal, indicated as ...

  • マニュアル

    ... connector. • Do not attach or remove the connector when the Unit is ON. Otherwise, Unit failure may occur. • You cannot directly connect the antenna cable. Connect it with the amplifier (V680-HA63), extension cable (V700-A4), or a dedicated cable (V700-A40-...

  • マニュアル

    ...Supply voltage Power consumption Ambient operating temperature Ambient operating humidity Ambient storage temperature Ambient storage humidity Insulation resistance Dielectric strength Vibration resistance V780-HMD68-EIP- V780-HMD68-ETN--S 250 × 250 × 70 mm (...

  • マニュアル

    ... dia. 85-mm dia. Beam gap 10 mm 20 mm 40 mm 80 mm Number of beams 15 to 199 8 to 124 6 to 38 4 to 12 Lens size 4.4  3.4 mm (W  H) 6.7  4.5 mm (W  H) Protective height 160 to 2,000 mm 240 to 1,520 mm 280 to 920 mm Model Performance Object resolution (Detection capability) Operating range Opaque objects 160 to 2,480 mm Long 0.3 to 10.0 m * 0.3 to 20.0 m Short 0.3 to 3.0 ...

  • マニュアル

    .../000000010> Clears the Trigger Input Count. None Gets the Match Count when the Matchcode function is used. The Response data output is V/ followed by a 9 digit value for the number of Matched strings. <...

  • マニュアル

    ... Bend Resistant cable (FHV-VNB2/FHV-VNLB2/FHV-VNB/FHV-VNLB, FHV-VDB2/FHVVDLB2/FHV-VDB/FHV-VDLB, FHV-VUB2/FHV-VULB2/FHV-VUB/FHV-VULB). LED Safety This product is classified into the following risk groups by IEC62471. Model Color Display FHV-LTM-...

  • マニュアル

    ...Power Station (Provided) Sensor Cable Shielded Cable (When connecting multiple units) Terminal Name Terminal Name Power Sensor Station KM Series * The terminal names may slightly differ depending on the type. KM Series Termination 120 Ω (1/2 ...

  • マニュアル

    ...The receive message settings are shown below. Note For details on receive message settings, refer to 3-4 Communication Message Attributes in the CX-Protocol Operation Manual (Cat. No. W344). Receive Message Setting Screen ● Settings for Receive Message “RV_RDCODE” Settings (...

  • マニュアル

    ... damage with direct and scattered beams and causing a fire". Item Specification MX-Z2000H-V1 Wavelength Remarks MX-Z2050H-V1 MX-Z2055H-V1 1062 nm Invisible laser Laser medium Yb: Fiber - Maximum output*1 40 ...

  • マニュアル

    ... damage with direct and scattered beams and causing a fire". Item Specification MX-Z2000H-V1 Wavelength Remarks MX-Z2050H-V1 1062 nm MX-Z2055H-V1 Invisible laser Laser medium Yb: Fiber - Maximum output*1 40 ...

  • マニュアル

    ... receive message settings are shown below. Note For details on the receive message settings, refer to 3-4 Communication Message Attributes in the CX-Protocol Operation Manual (Cat. No. W344). Receive Message Setting Screen ● Settings for Receive Message RV_RDCODE Settings (...

  • マニュアル

    ...) Impact Force: 150 m/s2, Test Direction: 6 directions, three times each (up/down, front/back, left/right) Degree of Protection IEC 60529 IP40 Main Body Only 59 g Packaging Weight Approx. 166 g (including packing) Main Body Dimensions 52 (...

  • マニュアル

    ... mm 064 Fixed Focus at 64 mm 081 Fixed Focus at 81 mm 102 Fixed Focus at 102 mm 133 Fixed Focus at 133 mm 190 Fixed Focus at 190 mm 300 Fixed Focus at 300 mm W Wide Field of View - 5.2 mm Focal Length Lens M Medium Field of View – 7.7 mm Focal Length Lens N Narrow Field of View – 16 mm Focal Length Lens 03M 752 x 480 (0.3 MP) Pixel, Mono Sensor, Global Shutter 12M 1280 x 960 (1.2 MP) Pixel, Mono Sensor, Global Shutter Y ZZZ Lens Sensor 50C 2592 ...