全 2908 件が検索されました。(2661 - 2680件を表示)
- マニュアル
...-V is used. Signal g name Signal direction Abbr. Input Pin no. Output Safety ground or earth ground GR --- --- 1 Signal ground or common return line SG --- --- 7 Send data SD --- Required 2 Receive data RD Required --- 3 Request send RS --- Required 4 Can send CS Required --- 5 Data terminal ready ER --- Required (20) ID Controller Host computer GR FG SG SG ...
- マニュアル
... below shows the pin assignment for the RS-232C connector on the rear panel of the Visual Controller. Pin number Old JIS code New JIS code Pin connection 1 2 Pin name GND --- Connector top view TXD SD Transmitted Data 3 RXD RD Received Data 4 RTS RS Request to Send 5 CTS CS Clear to Send 6 DSR DR Data Set Ready 7 GND SG Signal Ground 8 NC NC Protective Ground 9 (+14V) 10 (–14V) 20 DTR ER Data Terminal Ready Note Pin 9 and Pin 10 are used exclusively for the power supply of the Keyboard...
- マニュアル
... EIA RS-232C. Communications Signals 1 13 25 14 Signal Abbreviation Signal direction Pin no. Frame ground (safety ground) FG ––– 1 Signal ground or common return SG ––– 7 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 Data set ready DR Input 6 Data terminal ready ER Output 20 Connection Diagram The following diagram shows how the E5AX is connected to the host computer using the RS-232C. Host computer RS-232C Abbreviation E5AX RS-232C Pin no. Pin Abbrevino. ation 1 1 FG SG 7...
- マニュアル
....0 max. Keep the tightening torque to within 8 kg-cm. 3-6 RS-232C Interface Connection Signal name Abbr. I/O Pin no. Ground GR ––– 1 Signal ground SG ––– 9 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 ID Controller Host computer GR FG SG SG ...
- マニュアル
...2-1 Names and Functions of Parts Infrared window and LED indicators (front-transmitting type) DIP switch cover Terminal block cover Conduit Operation Indicators Name Color Function POWER Green Lit when power is supplied. ...
- マニュアル
...Transmission speed 19,200 bps max. Connector Pin Allocation Pin no. Connecting a Computer with a RS-232C I/F Unit 25 13 14 1 Signal name Name 1 FG (GND) Frame ground 2 SD (TXD) Send data 3 RD (RXD) Receive data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 DR (DSR) Data set ready 7 SG (GND) Signal ground 20 ER (DTR) Data terminal ready Connect the F300-VR as shown below. ...
- マニュアル
...Communications terminal RS-232C RDB 20 29 B(+) RD 19 28 RDA 19 28 A(–) 18 27 SG 18 27 SG 18 27 SG 17 26 SD 17 26 SDA 17 26 A(–) SG 16 25 SDB 16 25 B(+) 20 29 19 19 28 17 16 25 16 RS-485 20 29 20 18 RS-422 15 14 A 13 12 11 – B + B Use the E54-CT1 with a hole diameter of 5.8 mm or E54-CT3 with a hole diameter of 12 mm (both sold separately). 1. The E53-C cannot be used. 2. Only the ...
- マニュアル
...-SUB25 pin connectors. The XM2A-2501 Connector (made by OMRON) is recommended. The pin numbers and names are as shown below. Pin no. 25 13 14 1 Symbol Name 1 FG (GND) Frame Ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal Ground 8 CD (DCD) Data Carrier Detected 20 ER (DTR) Data Terminal Ready 41 Section 2-5 Connecting Peripheral Devices Wiring Standard 25-pin Cable Connection 9-pin Cable Connection F300-E RS-...
- マニュアル
...is recommended. The pin numbers and names are as shown below. Recommended Connectors: Manufacturer Model OMRON Pin no. XM2A-2501 25 13 14 1 Symbol Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal ground 20 ER (DTR) Data Terminal Ready 25 Section 2-4 Connecting Power Supply Unit I/O Terminals Use only shielded RS-232C cable. Wiring Standard 25-pin Cable Connection (F309-VR) F300-E2 9-pin Cable ...
- マニュアル
.... ’ ======================================================= ’ Data definition ’ ======================================================= X1=256:Y1=240 ’Initial rectangle region value X2=X1+63:Y2=Y1+63 ’Rectangle region size CN=20 ’Max. No. of the same characters N=40 ’Max. No. of characters DIM ...
- マニュアル
...Host Interface Connector Pin Layout (Diagram viewed from the insertion point.) Pin No. 2-6 Description 1 --- Abbreviation --- Signal direction 2 Receiving data RD Host device ← Hand-held Reader Writer 3 Sending data ...
- マニュアル
...Yes Yes Yes Yes 4-2 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 30 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring...
- マニュアル
...19 Section Wiring 4-1 4-2 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring Use only shielded RS-...
- マニュアル
... settings, I/O formats, and operating procedures. 4-2 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 32 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3...
- マニュアル
... female connectors. The pin numbers and names are shown below. Recommended OMRON Connector Model XM2A-0901 Hood XM2S-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...
- マニュアル
... female connectors. The pin numbers and names are shown below. Recommended OMRON Connector Model XM2A-0901 Hood XM2S-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...
- マニュアル
...:16 PM Section 4-1 Connector 4-1 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin 1 Signal FG (GND) Name Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 36 Model No. Plug XM2A-0901 Hood XM2S-0911 Z141-E1-03.book ...
- マニュアル
... D-SUB female connector. The pin allocation is shown below. 5 9 8 4 3 7 2 6 1 Pin 1 Signal Name FG Protective frame ground For RS-232C 2 SD 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2-3 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring The maximum cable length is 15 m for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin...
- マニュアル
... Average Measurement item Judge JG SeeAlso Meaning Judgement result Dens average AV Density average for measurement result Dens deviation DV Density deviation for measurement region Ref. average SA Density average when measurement region drawn Ref. deviation ...
- マニュアル
...-1-7 Connecting RS-232C Interface Signal Name Signal Direction Code Input Output Pin No. Ground for maintenance or ground GR — — Shield Ground for signal or common return SG — — 5 Send data SD — Receive data RD Request to send RS Clear to send CS 3 — — 2 7 — 8 Controller Pin Layout (TOP VIEW) Note 1: To prevent an operation error, ground the shielded wire either at the controller side or the computer side mentioned above. (The figure above shows an example of grounding the shielded wire at the ID controller side.) Note 2: Short-circuit pin No. 7 (RS) ...