全 2674 件が検索されました。(2521 - 2540件を表示)
- マニュアル
... are displayed in the "Setting model" area. 2 Measurement 3. The image specified for the model is displayed in the Image Display area. 5. To register two or more models, repeat the Steps Reference: 2(p.60) to Reference: 4(p....
- マニュアル
... performance flag Get/Set 0: OFF 1: ON 151 Edge level (defect width and depth edge measurement) Get/Set 0 to 100 152 Noise level (defect width and depth edge measurement) Get/Set 0 to 255 61 No. Data name Get/Set Range 153 Region width (defect width and depth edge measurement) Get only 0 to 10 154 Noise width (defect width and depth edge measurement) Get/Set 0 to 640 155 Corner judgement (start angle) Get/Set 0 to 30 156 Corner length Get/Set 0 to 9999 157 Corner judgement (start–end angle) Get/Set 0 to ...
- マニュアル
... and performs measurements. FQ User’s Manual Measurement region Max. color change: 25 Min. color change: 10 25 − 10 < 30 Judges that there is no edge (measurement result is NG). Inspecting with the Edge Position Inspection Item ...
- マニュアル
... 85 for details on setting the date and time. 9. AC/battery display : Running on AC or DC power supply. : Running on the battery. The remaining battery power is 100 to 91%. : Running on the battery. The remaining battery power is 90 to ...
- マニュアル
... keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 (7) ENTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
- マニュアル
.... . . . . . . . . . . 60 7-2 Setting the Measurement Trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 7-3 Setting the Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 7-4 Controlling the Sensor from an External Device . . . . . . . . . . . . . . . . . . . 68 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 2 FQ Short Manual 1 1-1 FQ-series Vision Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1-2 Measurement Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1-3 Startup Display and Display Elements . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1-4 Basic Operational Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Introduction Introduction 1-1 FQ-series Vision Sensors FQ-series Vision Sensors are real-color Vision Sensors with integrated processing. Once configured, they are used stand-alone for quality inspection of presence, position, and other product characteristics. To set up or...
- マニュアル
.... . . . . . . . . . . 60 Exportable and Importable File Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 FQ-M User’s Manual 11 3. Taking Images 3-1 Selecting a Sensor for Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 64 PC Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Touch Finder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 3-2 Adjusting Image Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Adjusting the Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Adjusting the Sensor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Displaying Guide Lines to Assist in Sensor Installation . . . . . . . . . . . . . . . . . . . 72 Adjusting Image Brightness with External Lighting . . . . . . . . . . . . . . . . . . . . . . 73 Taking Clear Images of Moving Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Improving the Image Quality of Metallic and other Shiny Surfaces . . . . . . . . . . 76 Adjusting the Colors of the Image (White Balance) . . . . . . . . . . . . . . . . . . . . . . 78 3-3 Synchronizing the Measurement Object Image Capture Timing. . . . . 79 Setting ...
- マニュアル
...Reference: Reference: Reference: Reference: Reference: Reference: Reference: Reference: Measuring folding of papers and sheets (p.60) Checking the interior/exterior and direction (p.60) Checking for mixing of different objects (p....
- マニュアル
...Parameter Settings (Measurement Image Switching) ………………………………………………52 Key Points for Test Measurement and Adjustment (Measurement Image Switching) ……………53 External Reference Tables (Measurement Image Switching) ………………………………………53 2. Measurement ……………………………………………………………………………………………55 Search ………………………………………………………………………………………………………57 Settings Flow (Search) …………………………………………………………………………………57 Model Registration (Search) ……………………………………………………………………………58 Region Setting (Search) …………………………………………………………………………………...
- マニュアル
.... . . . . . 60 3-5 Perform the Zero Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Zero reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
- マニュアル
...100 110 8 12.5 dia. Connector 24.5 20 98.1 10 Four, 4.5-dia. holes 185 䋨66.5䋩 2㬍7.62=15.24 148.38 8㬍7.7=61.6 23.3 50 3.85 44.8 10 䋨32.5䋩 9㬍7.7=69.3 99.5 Specifications and Dimensions 4.1 8 General specifications Power supply voltage 21.6 to 26.4 V DC Current consumption 1 A max. (with 2 sensors connected) *1 Insulation resistance Between the group of external DC terminals and the ground terminal: 20 MΩ ...
- マニュアル
... Menu Hierarchy Detect setting Measurement method p.45 Region p.47 Sensitivity p.48 Details p.51 Height/Reflectance p.54 Slant correct p.64 Height/position correct p.57 Reflectance correct p.61 Height p.69 Changing settings p.95 Step: 2 pts p.71 Calibration p.97 Step: 3 pts p.72 Output condition Edge position p.75 Clearing settings Width (OUT0 to 7) Upper p.107 Lower p.107 p.78 Hold p.109 Edge center p.81 Zero p.136 Peak/bottom p.82 Span p.105 Angel p.84 Offset p.105 Area p....
- マニュアル
.... . . . . . . . . . 56 3-3 Switching operation modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 3-4 Bank switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Multi-task and Bank Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Switching Banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 3-5 Perform the Zero Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Zero reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 3-6 Setting Threshold Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Threshold Value Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 3-7 Saving a project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Saving a project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Exporting a project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Importing a project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 3-8 Operating with Sensor Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 4.Settings for Function 4-1 Setting Sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Selecting the Area Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Setting the Material of the Target to Measure . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Setting the Noise Cut Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Setting Smoothing Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77...
- マニュアル
... muting input B d1 d2 d1: Distance between A1 and B1 d2: Distance between A1 and F3SG-RA All muting sensors are turned OFF and the safety function of the F3SG-RA is working. E F3SG-RA/RE User’s Manual ...
- マニュアル
...3-9. Reduced Resolution 53 3-10. Warning Zone 55 3-11. Operating Range Selection 57 3-12. Response Time Adjustment 57 3-13. Designated Beam Output 58 3-14. Setting Recovery 61 Chapter4 Monitoring with SD Manager 2 63 4-1. Incident/Ambient Light Level Monitoring 63 4-2. Maintenance Information 65 4-3. Muting Statistics Information 68 4-4. Operating Status Monitoring 72 Chapter5 viii Changing Settings with SD Manager 2 Appendix 75 5-1. Glossary 75 5-2. Revision History 79 SD Manager 2 User’s Manual Overview and Specifications Chapter 1 Overview and Specifications • Interface Unit ...
- マニュアル
...2 - 59 2 Creating Marking Data [Fixed point property] setting items [Form/Position] tab [Laser/Scan] tab Form setting page 2-60 Position setting page 2-60 Repeat setting page 2-60 Laser setting page 2-...
- マニュアル
... “Rib” for internal cable routing into conduit/duct. 18.2 (0.72) (Ref) 75.7 45° Cable to be routed through Aluminum Base conduit/duct. L=Nominal Mat Dimension 117.07 (PVC Trim Cvr) = L + (4.61) (Aluminum 138.43 TOL = - 0.381 / +0 =L+ Trim Base) (- 0.015 / +0) (5.45) (2.98) (Ref) Chapter Cable Conduit DIMENSIONS: mm (Inches) 5 Fig. 5-4 Installation Information for UMRT□ □ Care must be taken where wires are routed around the molded corners as these corners are fastened over the wiring. Safety Mat PVC Tri m Cover Corner MAT FASTENING DETAIL...
- マニュアル
... Monitor Setting Change - LASERPOWERCHECKSET (LCST) ......................... 8-57 Laser Power Monitor Setting Acquisition - LASERPOWERCHECKGET (LCGT) .................... 8-58 Traceability Log Setting Parameter Change - TRACEABILITYPARAMSET (TBST) ............... 8-59 Traceability Log Setting Parameter Acquisition - TRACEABILITYPARAMGET (TBGT).......... 8-60 Traceability Log Setting Acquisition - TRACELOGGET (TLGT) .............................................. 8-...
- マニュアル
... (unit: mm) [Calculation example] When K = 1,600 mm/s, Ts + Tc = 0.06 s, brake monitor setting time = 0.1 s, Tr = 0.008 s, and d = 25 mm: Tbm = 0.1 - 0.06 = 0.04 s Dpf = 3.4 x (25 - 7.0) = 61.2 mm S = 1,600 x (0.06 + 0.008 + 0.04) + ...
- マニュアル
...-12-1.Overview 38 2-12-2.Standard Muting Mode 40 2-12-3.Exit-Only Muting Mode 50 2-12-4.Position Detection Muting Mode 56 2-12-5.Dynamic Muting 60 2-12-6.Factory Default Setting 61 2-12-7.Setting with Configuration Tool ...