カタログ
PDF[-] F39-TC5 Data Sheet
...: 1.76 mm F39-TC5P01 9 6 F39-TC5 Safety Precautions !WARNING The muting and override functions disable equipment safety functions. Use separate procedures to ensure safety when the muting and override functions are operating. Position the Muting Sensors ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/f39-tc5_ds_e_4_1_csm1255.pdf

カタログ
PDF[F094-E1-13] F3SG-R Series Catalog
...Top/bottom adjustable bracket (for user-made mounting part) (sold separately) Standard adjustable bracket (sold separately) This bracket provides vertical as well as horizontal adjustment of ±15º. ±15° The wall mounting bracket k ket is not provided ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf

カタログ
PDF[-] F3SP-T01 Data Sheet
...Safety Precautions !WARNING Do not operate the product in atmospheres containing flammable or explosive gas. Arcs or heating of relays during switching may cause fire or explosion. Do not use a load that exceeds the contact ratings or switching capacity. Doing ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/f3sp-t01_ds_csm1256.pdf

カタログ
PDF[F089-E1-01] F3SR-B Catalog
...ON Safety output 1 OFF ON Safety output 2 OFF External Test Function OFF signal 40µs max. This function stops emission by test input. It creates a state in which the F3SR-B is blocked using external signals ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/f3sr-b_f089-e1_10_1_csm2138.pdf

カタログ
PDF[Q198-E1-09] Vision Accessory Catalog
...-brightness Models FL Series ●Maintaining light intensity even with long wiring distances Twice* Camera Brighter Light L Light 10-m long, distances result in voltage drops and lower light intensity. Power is supplied through the Camera, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/flv_fl_q198-e1_11_3_csm1017729.pdf

カタログ
PDF[Q198-E1-17] Vision Accessory Catalog
...-brightness Models FL Series Maintaining light intensity even with long wiring distances Twice* Camera Brighter Light L Light 10-m long, distances result in voltage drops and lower light intensity. Power is supplied through the Camera, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/flv_fl_q198-e1_13_1_csm1017729.pdf

カタログ
PDF[Q198-E1-22] Vision Accessory Catalog
...-brightness Models FL Series Maintaining light intensity even with long wiring distances Twice* Camera Brighter Light L Light 10-m long, distances result in voltage drops and lower light intensity. Power is supplied through the Camera, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/flv_fl_q198-e1_15_4_csm1017729.pdf

カタログ
PDF[Q183-E1-07] FQ-M Series Catalog
... Ethernet. The The FQ-M is able to output position communication wizard lets you easily coordinates and the correlative encoder configure any robot protocol both as a values and is able to manage the object server or as a client without complex queue, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/fq-m_q183-e1_11_9_csm1001277.pdf

カタログ
PDF[Q189-E1-02] FZ4 Series Catalog
... of important judgment values for inspections to easily manage and then adjust them later. Also, if you isolate in advance the settings that are critical to inspection performance (and normally known only to the designer) as user data, the locations that require adjustment can be clarified ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/fz4_q189-e1_14_4_csm1001568.pdf

カタログ
PDF[Q203-E1-07] FZ5 Series Data Sheet
... a personal computer or PLC. Connect a track ball, mouse and USB memory. A total of four USB ports are provided and any of them can be used. However, when connecting two or more USB memories, do not connect them to adjacent ports. Doing ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/fz5_q203-e1_13_1_csm1040804.pdf

カタログ
PDF[Q176-E1-02] FZ Series Catalog
....However, it is possible to extend the length (max. 15m) by jointing cables (max. 3 pieces), when using Camera Cable Extension Unit (FZ-VSJ). *2 This strobe controller is recognized as type FZ-SLC100 in FZ3-(H)3** / (H)7** series (previous ver2.12). And ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/fz_series_q176-e1-02.pdf

カタログ
PDF[Q177-E1-01] FZM1 Series Catalog
... are recognized as an edge code and geometric calculations determine the center of the circle and circumference edge. Even if the circle is broken, it is recognized as a circle, i.e., as the measurement object. Dirt and other abnormalities in the measurement region are differentiated ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/fzm1_q177-e1_10_1_csm2599.pdf

カタログ
PDF[-] G70R-SOC08 Data Sheet
... × 55 mm (W × H × D, when mounted upright). • Independent contacts and short bar allow easy common connections. • The common can now be connected with a short bar in the G70D-SOC08 and G70R-SOC08. • No tools are required to remove Relays, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g70r-soc08_ds_e_2_1_csm1046359.pdf

カタログ
PDF[J172-E1-03] G9SX-LM Data Sheet
... proximity sensors according to the following description: • To avoid interference from surrounding metal and mutual interference, specified proximity sensors should be correctly installed. • For handling of proximity sensors, see the instruction manual for the E2E. • Connect two proximity sensors of the same type. • Install proximity sensors ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g9sx-lm_j172-e1_6_2_csm1807.pdf

カタログ
PDF[-] H2C Data Sheet
... allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. • Be sure to wire the terminals correctly. • Do not install input lines in the same duct or conduit as power supply or other high-voltage lines. Doing ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h2c_ds_csm80.pdf

カタログ
PDF[-] H3AM Data Sheet
...: The Y92S-35 is not provided with H3AM. Order separately ,if water protection is required. Use Waterproof Packing to provide a level of water protection that complies with IP65 standards. Depending on the operating environment, the Waterproof Packing may deteriorate, contract, or harden and ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h3am_ds_e_3_1_csm83.pdf

カタログ
PDFh5an_ds_e_5_1_csm97.pdf
... output Control output (See note 2) (See note 2) Time up indication Time up indication Reset input indication Reset input indication Note: 1. For models with memory backup (H5AN-@M), you cannot perform a power-OFF reset, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5an_ds_e_5_1_csm97.pdf

カタログ
PDFh5cn_ds_e_5_1_csm99.pdf
... electric shock under specific conditions. Used for general prohibitions for which there is no specific symbol. Used for general mandatory action precautions for which there is no specified symbol. CAUTION Do not touch the terminals while power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5cn_ds_e_5_1_csm99.pdf

カタログ
PDFh5cz_l116-e1_6_3_csm2142.pdf
... separately) P3G-08 (order Waterproof Packing Flush Mounting Adapter separately) Back-connecting Socket Note: 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operation, it is recommended that Adapters be mounted ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5cz_l116-e1_6_3_csm2142.pdf

カタログ
PDF[-] H7AN Data Sheet
...Preset Preset Display Display 1st 1st 0 0 Count out 1st 1st Control outputs 2nd Count out Control outputs Count out Count out 2nd Note: Two-stage counters, set the counters so that the interval between 1st and 2nd count out will be more than 5 ms. For Incrementing/ Decrementing switchable counters, only the 2nd value will be effective if the 1st value is larger than the 2nd value. The Incrementing/Decrementing Counters give outputs in the following order; 1st to 2nd to 1st to 2nd. Totalizing Counters Incrementing/Decrementing selectable mode Incrementing mode Reversible mode Incrementing/Decrementing A, B, ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h7an_ds_e_4_6_csm115.pdf