ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2891 件が検索されました。(2061 - 2080件を表示)
マニュアル
PDF[H083-E1-03] E5AK Digital Controller User's Manual
...IBM-PC/AT DE-25 Female DTE RS-232C (RD) RXD 2 (SD) TXD 3 (ER) DTR 4 (SG) COMMON 5 (SD) TXD 2 (RD) RXD 3 (RS) RTS 4 (CS) CTS 5 (DR) DSR 6 (DR) DSR 6 (SG) COMMON 7 (ER) DTR 20 FG 1 F RS-422 20 SD 19 RD 18 SG (RS) RTS 7 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h083-e1-03_e5ak.pdf

マニュアル
PDF[H085-E1-03] E5EK Digital Controller User's Manual
...2 (SD) TXD 3 (ER) DTR 4 5 (SG) COMMON 5 (DR) DSR 6 (DR) DSR 6 (SG) COMMON 7 (SD) TXD 2 (RD) RXD 3 (RS) RTS 4 (CS) CTS (ER) DTR 20 FG 1 F RS-422 20 SD 19 RD 18 SG (RS) RTS 7 (CS) CTS 8 FG 1 No. 20 SD 19 RD 18 SG • Up to 32 controllers including a computer can be connected to the host computer. • The total cable length should not exceed 500 meters. • Use shielded twisted-pair cables (AWG28 or more) for the cables. • Attach terminators to the controllers at ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h085-e1-03_e5ek.pdf

マニュアル
PDF[H088-E1-02] E5AK Digital Controller (Programmable...
...IBM-PC/AT DE-25 Female DTE RS-232C (RD) RXD 2 (SD) TXD 3 (ER) DTR 4 (SG) COMMON 5 (SD) TXD 2 (RD) RXD 3 (RS) RTS 4 (CS) CTS 5 (DR) DSR 6 (DR) DSR 6 (SG) COMMON 7 (ER) DTR 20 FG 1 F RS-422 20 SD 19 RD 18 SG (RS) RTS 7 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h088-e1-02_e5ak.pdf

マニュアル
PDF[H089-E1-02] E5EK-T Digital Controller (Programmab...
...IBM-PC/AT DE-25 Female DTE RS-232C (RD) RXD 2 (SD) TXD 3 (ER) DTR 4 (SG) COMMON 5 (SD) TXD 2 (RD) RXD 3 (RS) RTS 4 (CS) CTS 5 (DR) DSR 6 (DR) DSR 6 (SG) COMMON 7 (ER) DTR 20 FG 1 F RS-422 20 SD 19 RD 18 SG (RS) RTS 7 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h089-e1-02_e5ek-t.pdf

マニュアル
PDF[H090-E1-01B] E5CK-T Digital Controller (Programma...
.... Ă• Use shielded twistedĆpair cables (AWG28 or more) for the cables. 25 pins E5CK-T IBM-PC/XT DE-25 Female DTE RS-232C No. (SD) TXD 2 (RD) RXD 3 (RS) RTS 4 (CS) CTS 5 (DR) DSR 6 (SG) COMMON 7 (ER) DTR 20 FG 1 F RS-485 13 SD 14 RD 1 SG Ă• 1:1 or 1:N connections are allowed. In a 1:N connection, up to 32 controlĆ lers including the host computer can be connected. Ă• The total cable length should not exceed 500 meters. Ă• Use shielded twistedĆpair cables (AWG28 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h090-e1-01b_e5ck-t.pdf

マニュアル
PDF[H119-E1-03] E5ZN-DRT DeviceNet™ Communications Un...
... allocated as Output Enable Bits). The IN Area is allocated for data such as the communications status and the process values of the Temperature Controller channels and the OUT Area is allocated for the set points of the channels and other data. When using a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h119-e1-03_e5zn-drt.pdf

マニュアル
PDF[I005-E1-02] 3G3XV-[][][][][]-EV2 Inverter Operati...
...IC 2 Date Match1993 July1993 March1994 January1996 Novemberig97 RevisedCOBtent Originalproduclion P8ge5:Dalユinthelableha5be巳ncorreCled' Pe冒e59宜11,12;lnv6rlefcapaCd旧S`r1いeIab:esbavθ b●encorrected, P8ge521.23:0v!pulchilvacter's!!...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i005-e1-02_3g3xv-_____-ev2.pdf

マニュアル
PDF[I527-E1-06] 3G3MV Multi-function Compact Inverter...
... 7 Communications Note In the above communications, the default is –1 (65535) and the LSB (least-significant byte) is converted as MSB (most-significant byte) (in the opposite direction). The CRC-16 check is automatically performed by using the protocol macro function of OMRON’s SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i527-e1-06_3g3mv.pdf

マニュアル
PDF[I528-E1-05] 3G3JV Compact Simplified Inverters Us...
... 7 Communications Note In the above communications, the default is –1 (65535) and the LSB (least-significant byte) is converted as MSB (most-significant byte) (in the opposite direction). The CRC-16 check is automatically performed by using the protocol macro function of OMRON’s SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i528-e1-05_3g3jv.pdf

マニュアル
PDF[I529-E1-02] 3G3MV-PDRT1-SINV1 DeviceNet Communica...
... performance, will lengthen product life, and may prevent possible accidents. Please read this manual thoroughly and handle and operate the product with care. For details about the 3G3MV Inverter and DeviceNet communications system, refer to the following manuals. SYSDRIVE 3G3MV User’s Manual (I527) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i529-02_3g3mv-pdrt1-sinv1.pdf

マニュアル
PDF[I531-E1-09] R88M-W[], R88D-WT[] AC Servomotors/Se...
... Driver. This enables the Servo Driver to be used as a network Servo Driver. 1-5 Introduction Chapter 1 A wide range of motion control can be achieved in a MECHATROLINK-II network from the Motion Control Unit. For details, refer to the SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i531-e1-09_r88m-w_r88d-w.pdf

マニュアル
PDF[I532-E1-01] 3G3RV High-Function General-Purpose I...
...15 VDC±10% Sink Current (mA) 16 mA Max Load impedance MP Sinking current AC 6-75 Communications Functions This section explains the individual communications functions. K Using RS-422A/485 Communications You can perform serial communications with SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i532-01_3g3rv.pdf

マニュアル
PDF[I533-E1-04] R7M-A[], R7D-AP[] Servomotors/Servo D...
...B24 A24 R7A–PR02A PARAMETER UNIT RESET B1 A1 Position Control Units CJ1W-NC113/213/413 CJ1W-NC133/233/433 CS1W-NC113/213/413 CS1W-NC133/233/433 C200HW-NC113/213/413 C500-NC113/211 SYSMAC CJ/CS/C/CV Programmable Controller Pulse String SCROLL JOG DATA RUN RUN READ DRIVER MODE/SET WRITE PR PR DRIVER R7A-PR02A Parameter Unit (Hand-held) SYSMAC Programmable Controllers with pulse outputs SYSMAC CPM2A SYSMAC CPM2C PA203 POWER / SMARTSTEP A-series R7D-AP@ Servo Driver SYSMAC CQM1H Single-shaft Positioner with pulse string output OPEN MS OPEN No. NS 3F88M- M0 1 AXIS...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i533-e1-04_r7m-a_r7d-ap.pdf

マニュアル
PDF[I560-E1-03] 3G3RX High-function General-purpose I...
...) 05: CF4 (multi-step speed setting binary 4) 06: JG (jogging) 07: DB (external DC injection braking) 08: SET (2nd control) 09: 2CH (2-step acceleration/deceleration) 11: FRS (free-run stop) 12: EXT (external trip) 13: USP (USP function) 14: ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i560-e1-03_3g3rx.pdf

マニュアル
PDF[I562-E1-09] R88M-G[], R88D-GT[] Servomotors/Servo...
...applications can be supported by one Servo Drive.  Simplified Speed Control with Internal Speed Settings Eight internal speed settings allow you to change the speed easily by using external signals. 1-1 1-2 System Configuration 1-2 System Configuration 1 SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i562-e1-09_r88m-g__r88d-gt_.pdf

マニュアル
PDF[I570-E1-02] MX2 Series Multi-function Compact Inv...
... (Multi-step speed 4) 06: JG (Jogging) 07: DB (External DC injection braking) 08: SET (Motor 2 control) 09: 2CH (2-step acceleration/deceleration) 11: FRS (Free-run stop) 12: EXT (External trip) 01 13: USP (USP function) (RV) 14: ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i570-e1-02_mx2_series.pdf

マニュアル
PDF[I608-E-03] SmartVision MX User's Guide
... x 492 1296 x 966 1294 x 964 Color / Mono- Color chrome Monochrome Frame Rate 120 fps 30 fps Trigger input Software / External Interface Gigabit Ethernet (1 Gbit/s) Lens Mounting C mount / CS mount 24114251 24114300 24114301 1/1.8inch CMOS 1-inch CMOS 1-inch CMOS 1602 x 1202 1600 x 1200 2048 x 2048 2046 × 2046 Color Monochrome Color Monochrome Color 30 fps 60 fps 60 fps 25 fps 25 fps Software Software / External C mount C mount / ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i608-e-03_smartvision_mx.pdf

マニュアル
PDF[I922-E1-03] 3G3RX → 3G3RX2 Replacement Guide
...11 FRS Free-run stop SF5 Multistage speed bit 5 12 EXT External trip SF6 Multistage speed bit 6 13 USP Power recovery restart prevention function SF7 Multistage speed bit 7 14 CS Commercial switch ADD Addition of frequency 15 SFT Soft lock SCHG Switching of instruction 16 AT Analog input switching STA 3-wire starting up 17 SET3 3rd control STP 3-wire stopping 18 RS Reset F/R 3-wire normal and reverse 19 - AHD Retention of analog instruction 20 STA 3-wire start FUP Acceleration through remote operation 21 STP 3-wire stop FDN Deceleration through remote ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i922-e1-03_3g3rx2_3g3rx.pdf

マニュアル
PDF[4449793-4G] K3TS リニアセンサ デジタルパネルメータ 取扱説明書(日/英語)
...Ambi郁thumidity Operatingl35%t・85%(withn・c・ndensati・n) ArnbientatmOSPhere Mustbefreeofcorrosi∨egas ・.Buin-insensorpowerSUPPIyト 80mAmax.at12VDC 一 ∼ 1 ) ハ } 、 〉 ノ 、、iI ♂嬬Jlひ》、ひー,トハ、 、 { ■Character`st`...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k3ts_inst-4449793-4g.pdf

マニュアル
PDF[1873445-6A] K5D-0800-S 自動通報装置 取扱説明書
...結線図(下図のいずれでも可) パソコン側 (D-Sub 9ピンメス) 信号 ピン略号 番号 CD RD SD ER SG DR RS CS CI 1 2 3 4 5 6 7 8 9 ※点線の配線は任意パソコン側 (D-Sub 9ピンメス) 信号 ピン略号 番号 CD RD SD ER SG DR RS ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k5d-0800-s_inst-1873445-6a.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。