ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む

絞り込み解除
全文検索:全 284 件が検索されました。(141 - 160件を表示)
マニュアル
PDF[W315-E1-03] C200H-MC221 Motion Control Unit Opera...
...1-2 Section 1-3 Indicators The following table shows the meaning of the indicators on the front of the Unit. Indicator RUN Color Green ERR Red X or Y CCW Orange g X or Y CW Orange g Status ON OFF ON OFF ON OFF ON OFF Meaning Initialization was completed normally and the connection of the MC Unit and the PC is normal. The MC Unit or PC has an error. An error occurred in the MC Unit. The MC Unit is operating normally. The motor is rotating counterclockwise. The motor is stopped or rotating counterclockwise. The motor ...

https://www.fa.omron.co.jp/data_pdf/mnu/w315-e1-03_c200h-mc221.pdf

マニュアル
PDF[W320-E1-03] CVM1-PRO01-V1 Teaching Box with CVM1...
...DRV.Z⋅U Connector MPG Connector Dedicated Cables for Drivers (see note 1) Battery for absolute encoder data backup (2.8 to 4.5 V) (see note 3) Servodriver External I/O MPG MPG: 1 channel CCW limit input ...

https://www.fa.omron.co.jp/data_pdf/mnu/w320-e1-03_cvm1_pro01_v.pdf

マニュアル
PDF[W334-E1-04] C200HW-NC113/NC213/NC413 Position Con...
...high-speed data transfers can also be performed by means of the Intelligent I/O Write (IOWR) and Intelligent I/O Read (IORD) instructions. 3 Section System Configuration 1-2 1-2 System Configuration The Position Control Unit receives control signals (...

https://www.fa.omron.co.jp/data_pdf/mnu/w334-e1-04_c200hw-nc.pdf

マニュアル
PDF[W397-E1-09] CJ1W-NC113/213/413/133/233/433 Positi...
... acceleration/decel- Not supported eration time for axis parameters until the target speed is reached Supported Supported Easy backup function Not supported Supported Supported Setting number of unused axes Not supported Not supported Supported Setting ...

https://www.fa.omron.co.jp/data_pdf/mnu/w397-e1-09_cj1w-nc.pdf

マニュアル
PDF[W398-E1-01] WS02-NCTC1-E CX-Position Operation Ma...
...Dedicated terminal block 7 1 23 5 4 26 25 24 External inputs 27 6 0 22 21 20 Dedicated terminal block 7 1-2 CCW limit input CW limit input Origin input Origin proximity input Emergency stop input Interrupt input CCW limit input ...

https://www.fa.omron.co.jp/data_pdf/mnu/w398-01_ws02-nctc1-e.pdf

マニュアル
PDF[W419-E1-04] CS1W-MCH71 Motion Control Unit Operat...
... 30 axes for controls. Computer MCH71 Memory card Sensor/ Valve W-series Servo + I/F unit PT Max.30 axes (nodes)/total length 50 m DI/O DI/O Counter Pulse output Stepping CW Limit/CCW Limit Note (1) The MECHATROLINK is registered trademark of YASKAWA ELECTRIC CORPORATION. (2) W-series servo driver requires YASKAWA MECHATROLINK-II I/F unit model JUSP-NS115. (3) Each of the products of the following version can be used. The version name is identified on the nameplates of each product. W-series servo driver: VER.39 or Later I/F unit: VER ***03 ...

https://www.fa.omron.co.jp/data_pdf/mnu/w419-e1-04_cs1w-mch71.pdf

マニュアル
PDF[W442-E1-01] FB Library Programmable Controller Re...
...7 Origin Compensation 8 Backlash Compensation 9 Backlash Compensation Speed 10 13 Acceleration/Deceleration Curve Origin Search Acceleration Time Origin Search Deceleration Time Positioning Monitor Time 14 CCW Software Limit 15 ...

https://www.fa.omron.co.jp/data_pdf/mnu/w442-e1-01_fb_library.pdf

マニュアル
PDF[W480-E1-09] CP1E-E[][](S)D[]-[]/N(A)[][]D[]-[]/N[...
...At start of operation NO 4 Search/Return Initial Speed 0 pps 0 pps At start of operation : 100,000 pps Origin Search Settings 1 Default Use define origin operation Do not use. 1-1 CW Possible settings Do not use. When setting is read by CPU Unit When power is turned ON Use. Search Direction ...

https://www.fa.omron.co.jp/data_pdf/mnu/w480-e1-09_cp1e.pdf

マニュアル
PDF[W545-E1-05] SYSMAC-XR002 Sysmac Library User's Ma...
...Setting value 16#0000 PTP (ABS) 16#0100 PTP (INC) 16#0101 Linear interpolation (ABS) 16#0200 Linear interpolation (INC) 16#0201 Circular interpolation (Border point/ABS) Circular interpolation (Border point/INC) Circular interpolation (Center/...

https://www.fa.omron.co.jp/data_pdf/mnu/w545-e1-05_sysmac-xr002.pdf

マニュアル
PDF[W572-E1-04] SYSMAC-XR012 Sysmac Library User's Ma...
... Values Set value 0 1 Descripition A forward direction command sets the motor rotation direction to clockwise. A forward direction command sets the motor rotation direction to counterclockwise. • The motor rotation direction when viewing the shaft from the load side is called clockwise (...

https://www.fa.omron.co.jp/data_pdf/mnu/w572-e1-04_sysmac-xr012.pdf

マニュアル
PDF[W579-E1-06] NX1P2-10[][][][](1)/11[][][][](1)/90[...
... to A3 in a circular motion on a 2D plane. Either absolute or relative positioning is possible. You can specify the circular interpolation mode, path direction, interpolation velocity, interpolation acceleration, interpolation deceleration, and combined jerk for the two axes. Y coordinate CCW ...

https://www.fa.omron.co.jp/data_pdf/mnu/w579-e1-06_nx1p2.pdf

マニュアル
PDF[W614-E1-03] CP2E-E[][]D[]-[]/S[][]D[]-[]/N[][]D[]...
...Origin Search Settings Name 1 Use define origin operation Default Do not use. Possible settings Do not use. When setting is read by CPU Unit When power is turned ON Use. 1-1 Search Direction CW CW At start of operation CCW 1-2 Detection Method Method 0 Method 0 At start of operation Method 1 Method 2 1-3 Search Operation Inverse 1 1-4 Operation Mode Mode 0 Inverse 1 At start of operation Inverse 2 Mode 0 At start of operation Mode 1 Mode 2 1-5 Origin Input Signal NC NC At start of operation NO...

https://www.fa.omron.co.jp/data_pdf/mnu/w614-e1-03_cp2e.pdf

マニュアル
PDF[Z199-E1-02] H8PS Cam Positioner Operation Manual
... and switches) during Run mode operation. This function prevents operation errors and protects the H8PS Cam Positioner from unauthorized operation. Refer to "3.11 All Protection Function". CHECK CAM STEP CAM STEP PRGM TEST RUN ADV ...

https://www.fa.omron.co.jp/data_pdf/mnu/z199-e1-02_h8ps.pdf

マニュアル
PDF[Z219-E1-05] V600-CHUD/CH1D-V2/CH1D-PSI Hand-held ...
...Command code Function Page EXPANSION BATCH BUTTON AUTO WRITE Writes up to 2 Kbytes of data to the Data Carrier in a batch when the Data Carrier enters the communications area after the activate switch is pressed. p.87 ...

https://www.fa.omron.co.jp/data_pdf/mnu/z219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

マニュアル
PDFRFID System V680 Series Hand-held Reader Writer
...A/H C/K DATA CHECK MD ST C/K DATA CHECK MD OVERWRITE COUNT CONTROL MD ST S/L OVERWRITE COUNT CONTROL MD S CALCULATION WRITE --- --- --- CALCULATION WRITE CW A/S ID CODE READ ID ST H ID CODE READ ID H READ WITH ERROR CORRECTION QR ST A/H --- --- --- WRITE WITH ERROR CORRECTION QW ST A/H --- --- --- V600 and V680 Command Comparison Command code Command name Communications specification Section 3 Communications Commands Communications Subcommands V680 commands Command name V600 commands Command code Data specification Command name Command code Data specification COMMAND PROCESSING TERMINATE AA --- COMMAND PROCESSING TERMINATE AA ---...

https://www.fa.omron.co.jp/data_pdf/mnu/z272-e1-09_v680-chud_ch1d.pdf

マニュアル
PDF[Z415-E1-08] MX-Z2000H-V1 series Fiber Laser Marke...
... beam is stared into deliberately". Item Specification MX-Z2000H-V1 Remarks MX-Z2050H-V1 MX-Z2055H-V1 Wavelength 655 nm Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type ...

https://www.fa.omron.co.jp/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf

マニュアル
PDF[Z416-E1-08] MX-Z2000H-V1 series Fiber Laser Marke...
... beam is stared into deliberately". Item Specification MX-Z2000H-V1 Remarks MX-Z2050H-V1 MX-Z2055H-V1 Wavelength 655 nm Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type ...

https://www.fa.omron.co.jp/data_pdf/mnu/z416-e1-08_mx-z2000h-v1.pdf

マニュアル
PDF[I513-E1-02] R88D-U Computer Monitor Software (Ver...
...-PRO2UorR88A・PRO3UParameterUnitwasbeingused 團AdjustingPa『amete『s 1.OpeningtheUserParameterAdjustmentWindow 6〔lcllselect【Parameter]一[userParameterAdjustment], 5・19 ---------------------[End of Page 4703]--------------------- Operation Chapter5 UserParameterAdjustmentwindowopens. ≡Met'・i+ArPArnmo.十⇔rAlamJortAuto五ningAdjustGraphq・・la・ii◎n AIt-XUUlt「ミタNe)ぐtWIrXコ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i513-e1-02_r88d-u.pdf

マニュアル
PDF[I538-E1-01] R88A-NCW152-DRT DeviceNet Option Unit...
... Reverse Rotation Mode, the direction of Servomotor rotation can be reversed without changing other items. The direction (+, -) of shaft motion is reversed. There are no other changes. Standard Setting Forward Command Reverse Rotation Mode CCW Position data from Servo Driver ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i538-e1-01_r88a-ncw152-drt.pdf

マニュアル
PDF[I611-E-07] LD-60/90 Platform User's Manual
... small white arc travels back and forth between the two ends of the green arc. Beacon blinks green (red if E-Stopped). 25% Platform Left Side 50% 75% Platform Right Side 100% State of Charge 0 to 90 cw...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i611-e-07_ld_platform.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。