ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む

絞り込み解除
全文検索:全 76 件が検索されました。(61 - 76件を表示)
マニュアル
PDF[W143-E1-07] C200H-LK, C500-LK, 3G2A5-LK, 3G2A6-LK...
...The example uses a multiple-link system, and the program is executed by Host Link Unit number 0. The following program is for NEC computers. For IBM compatibles, four lines must be changed as shown after the program. NEC 10 CLOSE #1 20 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w143-07_c200h-lk_c500-lk_3g2a6-lk.pdf

マニュアル
PDF[W186-E1-04] C500-ASC04 ASCII Unit Operation Manua...
... OFF the error indicators at Port 1 and Port 2 or error bits that are ON due to a transmission error or reception buffer overflow, execute the CLOSE statement. The END statement and the NEW command automatically close the ports, but the STOP statement does not. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w186-04_c500-asc04.pdf

マニュアル
PDF[W206-E1-04] CV500-BSC11/BSC21/BSC31/BSC41/BSC51/B...
... this stage, the BASIC Unit waits for input. The program is terminated when E is input. Configuration BASIC Unit CPU Rack CPU Unit Power Supply Computer with terminal mode Example Program 10 PARACT 0 15 ON ERROR GOTO *INERROR 20 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w206-e1-04_cv500_bsc11_21_31_41_51_61.pdf

マニュアル
PDF[W207-E1-02] CV500-BSC11/BSC21/BSC31/BSC41/BSC51/B...
...o @{「asノ〈-nμmbθrj Selectsatasktobedebugged. 29 AUTO AUTO[sfaπ一〃ηθ−nα]し∫ηcrθmθη司 Automaticallygenerateslinenumberswhenaprogramistypedin. 32 BREAK BREAK[{DELETE{ALLl"ηθイ70.[,〃ηe−η0.r}吻θ一η0.し〃ηe−η0.r}】 Sets,deletes,o川istsbreakpoints. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w207-e1-02_cv500-bsc.pdf

マニュアル
PDF[W235-E1-04] C200HS Programmable Controllers Opera...
... to receive the data. This program allows the computer to read and display the data received from the PC while a host link read command is being executed to read data from the PC. 10 ’C200HS SAMPLE PROGRAM FOR EXCEPTION 20 CLOSE 1 30 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w235-e1-04_c200hs.pdf

マニュアル
PDF[W365-E1-02] CQM1H-SCB41 Serial Communications Boa...
...receive the data. This program allows the computer to read and display the data received from the PC while a Host Link read command is being executed to read data from the PC. 10 ’CQM1H SAMPLE PROGRAM FOR EXCEPTION 20 CLOSE 1 30 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w365-e1-02_cqm1h-scb41.pdf

マニュアル
PDF[Z047-E1-04] 3Z4SP Visual Positioning Sensor Speci...
...Downloads measurement parameters DATAUP Uploads measurement parameters FLIST Lists functions MENU Return to menu mode WAIT Pauses program for a certain duration AUTO Automatically assigns a line number to each program line CLEAR Clears all variables ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z047-e1-04_3z4sp.pdf

マニュアル
PDF[Z048-E1-01] 3Z4SP Visual Positioning Sensor Refer...
... 255, the system regards it as 255. Comments ––– Reference CIRCLE, LINE, POLYGON, PSET Sample Program The system will draw a rectangle whose diagonal points are (100, 50) and (200, 150) on the Paint window screen (OVL–2). 10 DISPLAY 14 20 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z048-e1-01_3z4sp.pdf

マニュアル
PDF[Z082-E1-02] K3TS Communication Output-type Intell...
... *MAIN 1090 GOSUB *INIT 1100 GOSUB *MDAT 1110 GOSUB *COMM 1120 GOSUB *DISP 1130 GOSUB *QUIT 1140 IF FRG=0 THEN GOTO 1170 End judgment 1150 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z082-e1-02_k3ts.pdf

マニュアル
PDF[Z087-E1-01] V630 FA ID System Operation Manual
... can only be written in whole bytes and 2 HEX characters make up one byte. Up to 256 characters can be entered. Set the communication protocol of the R/W Head with its DIP switch to match the protocol of the host computer. 10 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z087-e1-01_v630.pdf

マニュアル
PDF[Z092-E1-02] F300 Visual Inspection System Referen...
... a circle. Graphic control Command 64 CLEAR Initializes variables. Memory management Command 65 CLNG Converts to a long integer. Calculation Function 65 CLOSE Closes an open file. File control Command 65 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z092-02_f300.pdf

マニュアル
PDF[Z104-E1-01] F200 Visual Inspection System Operati...
...9,600 bps Data length 8 bits Parity None Stop bits 1 Delimiter CR + LF ’*********************************************************************************** ’ (c)Copyright OMRON Co.1994 ’ All Rights Reserved ’ Sample Program ’Sample Program Using the Command Response Function ’*********************************************************************************** ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z104-01_f200.pdf

マニュアル
PDF[Z122-E1-01A] V600-CH1D Hand-held Reader Writer Op...
... only be written in whole bytes and 2 hexadecimal characters make up one byte. Up to 256 characters can be entered. Set the communication protocol of the Hand-held Reader Writer with its DIP switch to match the protocol of the host computer. 10 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z122-e1-01a_v600-ch1d.pdf

マニュアル
PDF[Z148-E1-06] V670-CD1D-V1/H11/H51(Q)/D13F03/D13F01...
...130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 ’***** V670-CD1D SAMPLE PROGRAM ***** CLS OPEN “COM:E73NN” AS #1 ’ ’***** MAIN LOOP **** *LOOP LINE INPUT “Input TX Data : “, ITD$ TXD$=ITD$+”*”+CHR$(13) PRINT “[TX] : “;ITD$ PRINT #1,TXD$; GOSUB *RECEIVE PRINT “[RX] : “;REC$ GOTO *LOOP ’ ’***** RECEIVE DATA ***** *RECEIVE RXD$=” “ WHILE (LOC(#1)=0):WEND WHILE (INSTR(RXD$,”*”+CHR$(13))=0) RXD$=RXD$+INPUT$(1,#1) WEND REC$=LEFT$(RXD$,LEN(RXD$)-2) RETRUN ’ END ’Opens a RS-232C port. ’Inputs a command data. ’Sets a data string ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z148-e1-06_v670-cd1d-v1_h11_h51(q)_d13f0_(h).pdf

マニュアル
PDF[Z253-E1-02] V500-R521B2/R521C2 Bar Code Reader Us...
...DR 6 Green SD CS 7 Red VCC RS 8 Black S.GND - 9 Shield F.GND Shield Cover 5VDC (Supplied from outside) 0V Example of BASIC program 100 CLS 110 CLOSE #1 120 OPEN "COM:N81NN" AS #1 130 BCDATA$="" 140 AA$=INPUT$(1,#1) 150 IF AA$=CHR$(&H03) GOTO 170 160 BCDATA$=BCDATA$+AA$:GOTO 140 170 PRINT "READ DATA=" ; BCDATA$ 180 GOTO 130 88 Signal name V500-R521B2/C2 User’s Manual V500-R521.book 89 ページ 2008年7月18日 金曜日 午後1時1分 Section 5...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z253-e1-02_v500-r521b2_r521c2.pdf

マニュアル
PDF[Z425-E1-01] FZ5 Series Vision System Macro Custom...
... strings as character strings type exceeds 255 characters. Syntax error is occurred when you specify wrong formatting; typographical error of macro function's name, no comma or no spaces. Usage Cautions None. Example Rem Close the Console Window. shell "cmd.exe /C ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z425-e1-01_fz5.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。