マニュアル
PDF[H155-E1-05] DeviceNet™ Communications Unit for EJ...
... message bytes is the number of data bytes following the FINS command code. The communications cycle time depends on whether remote I/O communications are being used. Message Communications Only (Remote I/O Communications Not Used) Message communications time = 2 (see note) + 0.11 × ...

https://www.fa.omron.co.jp/data_pdf/mnu/h155-e1-05_devicenet_ej1.pdf

マニュアル
PDF[N110-E1-02] K3HB-S Linear Sensor Indicator User's...
.... 000 Scaling display value A1 dsp. a1 21. 00 Scaling input value A2 inp. a2 20. 000 Scaling display value A2 dsp. a2 29. 00 Input type B in-tb 4-20 Scaling input value B1 inp. b1 4. 000 Scaling display value B1 dsp. b1 21. 00 Scaling input value B2 inp. b2 20. 000 Scaling display value B2 dsp. b2 29. 00 Constant K k 7000 Decimal point position dp ,,,. ,, Parameter Timing hold Remarks K-(A+B) Z4W-V25R Output (mA) 20 4 -4 nomal 4 Displacement (mm) Reference panel thickness 20 mm + sensor displacement 25 mm ...

https://www.fa.omron.co.jp/data_pdf/mnu/n110-e1-02_k3hb-s.pdf

マニュアル
PDF[SBCA-439E] NX-RS□□□□ ロードセル入力ユニット ユーザーズマニュアル
...プ端子台に固定してください。 電線の固定方法は 「電線の固定 (P.4-10)」を参照してください。 *2. 端子台に形 NX-TB1 を使用するときは、接地端子をより線で配線し、単線は使用しないでください。 導体長(ストリップ長) 使用上の注意 • ケー...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-439e-web1_nx-rs.pdf

マニュアル
PDF[SBCA-440F] NX-TS/HB アナログI/Oユニット ユーザーズマニュアル(温度入力ユニ...
...ユニット、ヒータ断線検知ユニット編(SBCA-440) 3 各部の名称と機能 端子台スクリューレスクランプ端子台には、形 NX-TB2 と形 NX-TB1 の 2 種類があります。 それぞれに 8 端子タイプ、12 端子タイプ、16 端子タイプの 3 種類の端子...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-440f-web1_nx-ts_hb.pdf

マニュアル
PDF[SBCA-480E] NYB□□-□□0/□□1/□□2/□□3/□□4, NYP□□-□□0/□...
...、SSD SLC C: 320GB、HDD D: 500GB、HDD E: 1TB、HDD F: 128GB、SSD 3D TLC G: 256GB、SSD 3D TLC H: 512GB、SSD 3D TLC K: 128GB、SSD MLC L: 256GB、SSD MLC M: 500GB、SSD MLC P: 1 TB、SSD 3DTLC 7 オプションインタフェース 0: 1: 2: 4: 6: 9: OS なし Windows Windows Windows Windows Windows Embedded Standard 7 - 32 ビット版 Embedded Standard 7 - 64 ビット版 10 IoT Enterprise 2016 LTSB - 64 ビット版 10 IoT Enterprise ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-480e_nyb_nyp.pdf

マニュアル
PDF[SBCD-312D] CVM1-DRM21-V1, C200HW-DRM21-V1 DeviceN...
...が長くなります。 ます。 注: 上図の A 部と B 部が別々のネットワークになっていた場合の通信サイクルタイムが TA、TB のとき、上図のネットワークの通信サイクルタイムは TA+TB となります。 ネットワーク構築 従来どおりです。 上の留意点 「3-...

https://www.fa.omron.co.jp/data_pdf/mnu/sbcd-312d-13_cvm1_c200hw-drm-v1.pdf

マニュアル
PDF[SBCD-357C] CJ1W-DRM21 DeviceNetユニット ユーザーズマニュアル(NJ...
...意してくだす。 注. 上図の A 部と B 部が別々のネ さい。 ットワークになっていた場合の通信サイクルタイムが TA、TB のとき、上図のネットワークの通信サイクルタイムは TA+TB となります。 ・同一のスレーブを複数のマスタで共有することは...

https://www.fa.omron.co.jp/data_pdf/mnu/sbcd-357c-web1_cj1w-drm21.pdf

マニュアル
PDF[SDNC-753G (84-9000363-02)] V450-H/V410-Hシリーズ ハンディ...
...水素 • ベンゼン • 漂白剤 • 石炭酸 • アミンまたはアンモニアの化合物 • エタノールアミン • エーテル • ケトン • TB- リゾフォルム • トルエン • トリクロロエチレン 承認されている洗浄剤次の洗浄剤は、 Omron Microscan 製品の洗浄に適していると承認されています。 • ...

https://www.fa.omron.co.jp/data_pdf/mnu/sdnc-753g(84-9000363-02)_v450-h_v410-h.pdf

マニュアル
PDF[SGFM-711H] NX-SL□□□□ セーフティコントロールユニット コマンドリファレンスマニ...
...NO A T B1 B ND 2 NO T B1 AND NOT B2 NOTB1 AND B2 ) B2 Button 1 Released 2 B 1 8008 AN 8019 B1 OR 1 TB NO 1 2 2) 1 Locked On 1 (B 3 2 1 DB AN 2 T NO 2 B ND A B1 RB NOT (B1 OR B2) 1 3 Locked Off 8009 B1 O B2 B1 A NOT (B1 OR B2) 3 Error C001 B1 C002 B2 C003 B1&B2 S_TwoHandOut=FALSE S_TwoHandOut=TRUE 3 1 Buttons 2 Actuated 8000 B1=S_Button1 B2=S_Button2 (注)「Activate」=...

https://www.fa.omron.co.jp/data_pdf/mnu/sgfm-711h_nx-sl.pdf

マニュアル
PDF[SGTD-733E] EJ1 DeviceNet™通信ユニット ユーザーズマニュアル
...能 ■ メッセージ通信のみを実行するとき(リモート I/O 通信停止中のとき) 通信サイクルタイム=2 注+0.11×TB+0.6 [ms] TB :500k ビット/s 時=2、250k ビット/s 時=4、125k ビット/s 時=8 (通信速度によって異なる) 注:リモート I/O 通信停止時の通信サイクルタ...

https://www.fa.omron.co.jp/data_pdf/mnu/sgtd-733e_ej1.pdf

マニュアル
PDF[SGTE-705B] K3HB-S 高速応答デジタルパネルメータ ユーザーズマニュアル
...21. 00 スケーリング入力値 A2 inp. a2 20. 000 スケーリング表示値 A2 dsp. a2 29. 00 入力種別 B in-tb 4-20 スケーリング入力値 B1 inp. b1 4. 000 スケーリング表示値 B1 dsp. b1 21. 00 スケーリング入力値 B2 inp. b2 20. 000 スケーリング表示値 B2 dsp. b2 29. 00 定数 K k 7000...

https://www.fa.omron.co.jp/data_pdf/mnu/sgte-705b-1_k3hb-s.pdf

マニュアル
PDF[W347-E1-06] C200HW-DRT21, CQM1-DRT21, DRT1 Series...
... total of the processing time of each Slave in the network. MULTIPLE I/O TERMINAL processing time: 3.5 [ms] Only when Slaves with input, output, or mixed I/O of more than 8 bytes exist. Explicit messages processing time: 0.11 × ...

https://www.fa.omron.co.jp/data_pdf/mnu/w347-e1-06_c200hw_cqm1-drt_drt1.pdf

マニュアル
PDF[W379-E1-03] CVM1-DRM21-V1, C200HW-DRM21-V1 Device...
...” for all the Slaves in the network. High-density Unit Processing Time: 3.5 [ms] This is added if there are any Slaves in the network that use at least 8 bytes for input, output, or both. Explicit Message Communications Time: 0.11 × ...

https://www.fa.omron.co.jp/data_pdf/mnu/w379-e1-03_cvm1_c200hw-drm-v1.pdf

マニュアル
PDF[W384-E1-01] CS1W-HIO01/HCP22/HCA22 Customizable C...
...TR TR 0 25506 01001 0 25507 01002 TABLE COMPARE – TCMP(85) Operand Data Areas CD: Compare data Ladder Symbols IR, SR, DM, EM, TIM/CNT, LR, # TCMP(85) @TCMP(85) CD CD TB TB R R TB: First comparison table word IR, SR, DM, EM, TIM/CNT, LR R: Result word IR, SR, DM, EM, TIM/CNT, LR Limitations DM 6144 to DM 6655 cannot be used for R. Description When the execution condition is OFF, TCMP(85) is not executed. When the execution condition is ON, TCMP(85) compares CD to the content of ...

https://www.fa.omron.co.jp/data_pdf/mnu/w384-e1-01_cs1w-hio01_hcp22_hca22.pdf

マニュアル
PDF[W483-E1-08] CP1E-E[][]D[]-[]/N(A)[][]D[]-[], CP2E...
...@CTBL Function code Function CTBL(882) is used to register a comparison table and perform comparisons for a high-speed counter PV. 882 CTBL CTBL(882) Symbol P P: Port specifier C C: Control data TB TB: First comparison table word Applicable Program Areas Area Function block definitions Step program areas Subroutines Interrupt tasks Usage OK OK OK OK Operands Operand Description P Port specifier C Control data ...

https://www.fa.omron.co.jp/data_pdf/mnu/w483-e1-08_cp1e_cp2e.pdf

マニュアル
PDF[W486-E1-02] CJ2M-CPU[][]/MD21[] CPU Unit Pulse I...
... Instruction: CTBL(882) The CTBL(882) instruction compares the PV of a high-speed counter (0 to 3) to target values or ranges and executes the corresponding interrupt task (0 to 255) when the specified condition is met. Execution condition @CTBL P C ...

https://www.fa.omron.co.jp/data_pdf/mnu/w486-e1-02_cj2m-cpu_-md21_.pdf

マニュアル
PDF[W497-E1-03] CJ1W-DRM21 DeviceNet Units Operation ...
... Units connected to a single CPU Unit • The communications cycle time is longer. • Make sure that each word allocated in the system is allocated to only one Master Unit. Note The communications cycle time for the network in the figure above is TA+...

https://www.fa.omron.co.jp/data_pdf/mnu/w497-e1-03_cj1w-drm21.pdf

マニュアル
PDF[W556-E2-08] NY512-1[]00 Industrial Box PC User's ...
...-4 Product Configuration Item Option / Description 15 Storage 6: 128 GB CFast MLC 7: 256 GB CFast MLC 8: 32 GB, SSD SLC 9: 64 GB, SSD SLC C: 320 GB, HDD K: 128 GB, SSD MLC P: 1 TB, SSD 3D TLC 16 Optional interface 0: None 1: RS-232C 2: DVI-D 6: NY Monitor Link 17 Logo 0: OMRON 2: Customization X: No display (Industrial Box PC) NY-series Industrial Box PC Machine Controller Hardware User's Manual (W556) 1 1-7 1 Introduction to the Box PC 1-5 Overall Operating Procedure This section gives ...

https://www.fa.omron.co.jp/data_pdf/mnu/w556-e2-08_ny512-1_00.pdf

マニュアル
PDF[W557-E2-10] NY532-1[]00/5400 Industrial Panel PC ...
...1-8 Description Option / Description 15 Storage 6: 128 GB CFast MLC 7: 256 GB CFast MLC 8: 32 GB, SSD SLC 9: 64 GB, SSD SLC C: 320 GB, HDD K: 128 GB, SSD MLC P: 1 TB, SSD 3D TLC 16 Optional interface 0: None 1: RS-232C 2: DVI-D 6: NY Monitor Link 17 Logo 0: OMRON 2: Customization X: No display (Industrial Box PC) NY-series Industrial Panel PC Machine Controller Hardware User's Manual (W557) 1 Introduction to the Panel PC 1-5 Overall Operating Procedure 1-5 Overall Operating Procedure This section gives ...

https://www.fa.omron.co.jp/data_pdf/mnu/w557-e2-10_ny532.pdf

マニュアル
PDF[W565-E1-05] NX-RS[][][][] Load Cell Input Unit Us...
... mm mm2 (AWG 28 to 16) 2.0 mm2 9 to 10 mm *1. Secure wires to the screwless clamping terminal block. Refer to Securing Wires on page 4-11 for how to secure wires. *2. With the NX-TB1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length) 4-6 NX-series Load Cell Input Unit User’s Manual (W565) 4 Installation and Wiring Precautions for Correct Use • Use cables with suitable wire sizes for the carrying current. There are also restrictions on ...

https://www.fa.omron.co.jp/data_pdf/mnu/w565-e1-05_nx-rs.pdf