ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2766 件が検索されました。(1861 - 1880件を表示)
マニュアル
PDF[I515-E1-03] 3G3HV High-capacity General-purpose I...
...3-60 50.0 to 400.0 [60.0] 3-60 0.1 to 255.0 [200.0] (See note 1.) 0.2 to 400.0 [60.0] 3-60 0.1 to 399.9 [3.0] 3-61 0.1 to 255.0 [15.0] (See note 1, 2.) 3-61 0.1 to 10.0 [1.5] 3-61 0.1 to 50.0 [10.0] (See note 1, 2.) 3-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i515-03_3g3hv.pdf

マニュアル
PDF[I516-E1-05] 3G3FV High-function General-purpose I...
...from the motor speed.) Set “1” to use the speed search function. To use speed search freely in control modes without PG, i.e., V/f control and open-loop vector control, set the multi-function contact input selection (H1-01 to H1-06) to ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i516-e1-05_3g3fv.pdf

マニュアル
PDF[I524-E1-04] FND-X[]/X[]-SRT Position Drivers User...
...24 VDC Output current: 40 mA Origin proximity Deceleration stop 24 VDC 8 mA Note The Servomotor cannot be driven if the deceleration stop signal if OFF for the external control input (CN4-4) or the CompoBus/S input (OUT7). 2-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i524-04_fnd-x__x_-srt.pdf

マニュアル
PDF[I528-E1-05] 3G3JV Compact Simplified Inverters Us...
... RS-422/485 port SYSMAC C200HX/HG/HE SYSMAC CQM1H C200HW-COM06-EV1 Note Make sure that the model number has the suffix “EV1,” otherwise the CRC-16 check code cannot be used. CQM1H-SCB41 (Used on CQM1H-CPU51/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i528-e1-05_3g3jv.pdf

マニュアル
PDF[I529-E1-02] 3G3MV-PDRT1-SINV1 DeviceNet Communica...
... level 0.00 to 400.0 0.01 Hz 0.00 No n096 0160 01 60 Overtorque detection function selection 0 to 4 1 1 0 No n097 0161 01 61 Overtorque detection function selection 0, 1 2 1 0 No n098 0162 01 62 Overtorque detection level 30 to 200 1% 160 No n099 0163 01 63 Overtorque detection time 0.1 to 10.0 0.1 s 0.1 No n100 0164 01 64 UP/DOWN frequency selection 0, 1 1 0 No n101 0165 01 65 Speed search deceleration time 0.0 to 10.0 0....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i529-02_3g3mv-pdrt1-sinv1.pdf

マニュアル
PDF[I531-E1-09] R88M-W[], R88D-WT[] AC Servomotors/Se...
...50 78 60 90 70 62 33 17 3 19 30 M6 20 22 6 6 3.5 1/25 R88M-W40030j -jG25CJ 124.5 164 104 61 98 60 115 90 75 43 18 5 24 40 M8 20 30 8 7 4 1/5 R88M-W75030j -jG05CJ 145 189.5 93.5 50 78 80 90 70 62 33 17 3 19 30 M6 20 22 6 6 3.5 1/9 R88M-W75030j -jG09CJ 145 189.5 97.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i531-e1-09_r88m-w_r88d-w.pdf

マニュアル
PDF[I532-E1-01] 3G3RV High-Function General-Purpose I...
... Speed When Frequency Reference Is Lost ........... 6-58 Restarting Operation After Transient Fault (Auto Restart Function) ............................ 6-58 Inverter Protection ...................................................................................... 6-60 u Performing Overheating Protection on Mounted Braking Resistors............................. 6-60 u Reducing Inverter Overheating Pre-Alarm Warning Levels ......................................... 6-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i532-01_3g3rv.pdf

マニュアル
PDF[I533-E1-04] R7M-A[], R7D-AP[] Servomotors/Servo D...
...30 M5 M6 M5 M6 M4 M4 20 20 22 22 6 6 6 6 3.5 1.7 3.5 2.1 1/25 R7G-VRSFPB25D400 1/5 R7G-VRSFPB05C750 104 61 93.5 50 98 78 60 80 70 90 115 90 90 70 75 62 18 17 5 3 8 24 10 19 40 30 M5 M8 M6 M6 M4 M4 20 20 30 22 8 6 7 6 4 3.2 3.5 2.1 1/9 R7G-VRSFPB09D750 1/15 R7G-VRSFPB15D750 97.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i533-e1-04_r7m-a_r7d-ap.pdf

マニュアル
PDF[I544-E1-06] R88M-W[], R88D-WN[]-ML2 AC Servomotor...
...78 60 90 70 62 1/15 R88M-W40030@-@G15CJ 124.5 164 100 50 78 60 90 70 62 1/25 R88M-W40030@-@G25CJ 124.5 164 104 61 98 60 115 90 75 1/5 R88M-W75030@-@G05CJ 145 189.5 93.5 50 78 80 90 70 62 1/9 R88M-W75030@-@G09CJ 145 189.5 97.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i544-e1-06_r88m_w_r88d_wn_ml2.pdf

マニュアル
PDF[I547-E1-02] 3G3JE EasySpeed Compact Simplified In...
... table are used for the fundamental frequency input current and converted for a received voltage of 6.6 kV. Applicable motor [kW] Fundamental frequency input current [A] 200 V 400 V Value converted for 6.6 kV [mA] 0.4 1....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i547-e1-02_3g3je.pdf

マニュアル
PDF[I553-E1-01] R7M-Z[], R7D-ZP[] Servomotors/Servo D...
...50 78 60 70 90 70 62 17 3 8 19 30 M5 M6 M4 20 22 6 6 3.5 2.1 1/25 R7G-VRSFPB25D400 104 61 98 60 70 115 90 75 18 5 8 24 40 M5 M8 M4 20 30 8 7 4 3.2 1/5 R7G-VRSFPB05C750 93.5 50 78 80 90 90 70 62 17 3 10 19 30 M6 M6 M4 20 22 6 6 3.5 2.1 1/9 R7G-VRSFPB09D750 97.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i553-e1-01_r7m-z_r7d-zp.pdf

マニュアル
PDF[I554-E1-01] R7D-ZN[]-ML2 Servomotors/Servo Driver...
...50 78 60 70 90 70 62 17 3 8 19 30 M5 M6 M4 20 22 6 6 3.5 1/25 R7G-VRSFPB25D400 104 61 98 60 70 115 90 75 18 5 8 24 40 M5 M8 M4 20 30 8 7 4 1/5 R7G-VRSFPB05C750 93.5 50 78 80 90 90 70 62 17 3 10 19 30 M6 M6 M4 20 22 6 6 3.5 1/9 R7G-VRSFPB09D750 97.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i554-e1-01_r7m-z_r7d-zn.pdf

マニュアル
PDF[I558-E1-02] 3G3JX Compact Simplified Inverters Us...
... command status prior to the input. •If you switch on/off this function during operation, the RUN command is reset to stop the Inverter. Before resuming operation, stop the RUN command from each command source to avoid possible danger and then input it again. 4-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i558-e1-02_3g3jx.pdf

マニュアル
PDF[I559-E1-02] 3G3MX Multi-function Compact Inverter...
... (network error) 09: LOG(logic operation output) 00: Output frequency 01: Output current Default setting Changes during operation Unit Page No ⎯ 4-53 No ⎯ 4-31 4-63 No ⎯ 4-61 00 01 05 00 00 00: NO contact at MA; NC contact at MB 01: NC contact at MA; NO contact at MB 00 01 0.0: Does not operate 0.1 × Rated current to 2.0 × Rated current Rated current 4-29 4-55 No A C241 *2nd overload warning level Rated current C042 Arrival frequency during acceleration 0.0 to 400.0 0.0...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i559-e1-02_3g3mx.pdf

マニュアル
PDF[I560-E1-03] 3G3RX High-function General-purpose I...
...When the FW signal is ON, the motor runs forward. When it is OFF, the motor decelerates and stops. S1 S2 S3 S4 S5 S6 S7 S8 Multi-function input Select 8 functions from among the 61 functions and allocate them to terminals S1 to S8. Note: Only terminals S1 and S3 can be used for the emergency shutoff function. For details, refer to "Emergency Shutoff Function" (page 2-10). Status / Factor Input impedance between each input terminal and the PSC terminal: 4.7 kΩ Allowable max. voltage: Voltage between each input terminal and the PSC terminal: 27 V DC...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i560-e1-03_3g3rx.pdf

マニュアル
PDF[I562-E1-09] R88M-G[], R88D-GT[] Servomotors/Servo...
...78 70 90 70 3 8 19 30 1/5 R88G-VRXF05C750CJ 93.5 50 80 78 90 90 70 3 10 19 30 1/9 R88G-VRXF09D750CJ 97.5 61 80 98 90 115 90 5 10 24 40 1/15 R88G-VRXF15D750CJ 110.0 61 80 98 90 115 90 5 10 24 40 1/25 R88G-VRXF25D750CJ 110.0 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i562-e1-09_r88m-g__r88d-gt_.pdf

マニュアル
PDF[I566-E1-07] R88M-G[], R88D-GN[]-ML2 AC Servomotor...
...90 70 3 8 19 30 1/5 R88G-VRXF05C750CJ 93.5 50 80 78 90 90 70 3 10 19 30 1/9 R88G-VRXF09D750CJ 97.5 61 80 98 90 115 90 5 10 24 40 1/15 R88G-VRXF15D750CJ 110.0 61 80 98 90 115 90 5 10 24 40 1/25 R88G-VRXF25D750CJ 110.0 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i566-e1-07_r88m-g_r88d-gn_-ml2.pdf

マニュアル
PDF[I570-E1-02] MX2 Series Multi-function Compact Inv...
...no yes Hz A069 Acceleration 0.00 to 99.99 Stop Frequency 100.0 to 400.0 (1000.) 0.00 no yes Hz A070 Acceleration Stop Time 0.0 5-60 4 5-61 0.0 to 60.0 SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@) Parameter List Others Limit/jump Parameter No. Function name Data can Data can be Default be set Set data changed Unit Page setting during during RUN RUN 5-62 no yes s 4-10 4-2 Function Mode PID control Parameter No. Function name Parameter List 4 A071 PID Selection 00: Disabled 01: ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i570-e1-02_mx2_series.pdf

マニュアル
PDF[I591-E-05] Cobra 350 Robot User's Guide
...Belt Encoder 1 Connector 05624-000 Rev. K n/a Standard Option X 09443000 Cobra 350 User's Guide X X X X HDB26 Female DB15 Female M12 Female, 8-pin 61 5.3 Optional Cables Item Description Part # Standard Option Usersupplied Notes H Belt Encoder 2 Connector I SmartController EX (optional) 19300000 X J SmartController EX Belt 09550Encoder Y Adapter Cable Con- 000 nector X K Belt Branch Connector, Encoder 1 and 2 DB15 Male L Belt Branch Connector, Encoder 3 and 4 DB15 Male C PIN 8 PIN 15 PIN 15 PIN 7 PIN 14 PIN 6 PIN ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i591-e-05_cobra_350.pdf

マニュアル
PDFi668-e-01_v%2b.pdf
...-56 pm.src.clear..........................................................................................................................4-78 4-57 pm.src.clearall......................................................................................................................4-79 4-58 pm.trg.avail...........................................................................................................................4-80 6 V+ Module Reference Manual (I668) CONTENTS 4-59 pm.trg.done ..........................................................................................................................4-81 4-60 pm.trg.get .............................................................................................................................4-82 4-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i668-e-01_v+.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。