全 5977 件が検索されました。(1841 - 1860件を表示)
- マニュアル
...) The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting parameter will operate. Initial Setting Level Platinum resistance thermometer Pt100 JPt100 Thermocouple ...
- マニュアル
... shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting parameter will operate. Operation Menu Initial Setting Level Input Type Platinum resistance thermometer Input Pt100 JPt100 Thermocouple ...
- マニュアル
... Setting Level Input EV1 EV2 Lit when the Auto/Manual Mode is set to Manual Mode. CT1 Bar Display: Displays the MV or heater current in 10 steps. Platinum resistance thermometer Pt100 JPt100 Thermocouple ...
- マニュアル
...SP X SP X 0 0 X X 0 X 0 X 0 X 0 0 0 X X ON OFF ON OFF SP X K SP Vary with "L", "H" values ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF JPt100 X Vary with "L", "H" values ON OFF Pt100 X SP X SP X X X J Temperature inputs *1 0 Input type 0 0 0 X 0 X 0 X X X 0 0 0 *1: Upper and lower limits can be set for parameters 1, 4 and ...
- マニュアル
...0RGHkey Press this key to change the contents of the display. Press this button for s or longer for reverse scroll. Operation menu ,QLWLDO6HWWLQJ/HYHO Input type Input type Input 3W Platinum resistance thermometer -3W ...
- マニュアル
...ᅮϡӮᕅડ䖤㸠DŽ 1 ⾏أϞϟ䰤 2 ⾏أϞ䰤 3 ⾏أϟ䰤 4 ⾏أϞϟ㣗ೈ 5 ⾏أϞϟ䰤ᕙ ᴎᑣ߫ON 6 ⾏أϞ䰤ᕙᴎ ᑣ߫ON K ⾏أϟ䰤ᕙᴎ ᑣ߫ON J 䕧ܹ K J, L 䆒ᅮؐ 0 1 2 3 4 5 6 7 8 9 * 咬䅸ؐᰃĀ2āDŽ g䪖⬉䰏⏽ᑺ䅵ൟ ˄E5CS-ƶPU˅ 䆒ᅮ㣗ೈ °C 0̚200 0̚300 0̚400 0̚500 0̚600 0̚999 0~200 0~300 0~400 0~500 °F 0~200 0~300 0~400 0~500 0~600...
- マニュアル
...Input type 6 Scale indication 5 No alarm output OFF Upper and lower limit alarm X OFF OFF ON PID control 20 seconds 2 seconds Reverse Normal 2 Disable Enable Thermocouple: K,J Thermocouple: K,L Lower limit alarm 4 Upper and lower limit range alarm 5 °F Upper limit alarm 3 Resistance thermometer: JPt100 Resistance thermometer: Pt100 • All switches are OFF by default. • The optimum proportional band is set automatically and offset is adjusted automatically in the PID control. • The input shift value is valid even if the input shift display is disabled. To disable the input shift, set ...
- マニュアル
... unit into the Terminal • DIN track PFP-100N (100 cm) PFP-50N (50 cm) Unit. Incorrect Incorrect 14 11 15 12 16 B + mA 11 15 12 16 B Pt100 JPt100 Thermocouple K J Temperature inputs Setting range Setting T E L U 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 °C °F -200 to 850 -199.9 to 500.0 0.0 to 100.0 -199.9 to 500.0 0.0 to 100.0 -200 ...
- マニュアル
... Unit (E5DC-SCT1S) • Up and Down keys 120 min 2 DIN track(sold separately) Individual mounting : PFP-100N(100cm) PFP-50N(50cm) Initial Setting Level Input type Platinum resistance thermometer Input Pt100 JPt100 Thermocouple ...
- マニュアル
...ᴶཝ±1փᮦ 䫸⭫䱱䗉ޛφ δᱴ⽰Ⲻٲ±0.2αᡌ㘻±0.8°CѣⲺ䖹ཝٲε ᴶཝ±1փᮦ ⁗ᤕ䠅䗉ޛφ±0.2 % FS ᴶཝ±1փᮦ 䗉࠰⭫⍷φ∅Ѡ䀜⛯㓜7 mAȾ ONφᴶཝ1 k:θOFFφᴶቅ100 k: ONφ⇁֏⭫ুᴶཝ1.5 V OFFφ╅⭫⍷ᴶཝ0.1 mA 4Њ20 mA DCᡌ0Њ20 mA DC 0Њ5 VDCᡌ1Њ5 VDCᡌ0Њ10 VDC 㔝⭫ಞ䗉࠰φSPST-NO, 250 VACθ5 Aδ䱱ᙝ䍕䖳ε 㔝⭫ಞ⭫≊ስળφ100,000⅗䘆㺂 ⭫ু䗉࠰δ⭞...
- マニュアル
... level. • Hold the M key and the D key together for at least 1 second to switch Run/Reset. Operation Menu Initial Setting Level Input Type Input type Platinum resistance thermometer Input Setting Pt100 JPt100 Thermocouple ...
- マニュアル
...用调试工具。 ·菜单键 输入类型铂电阻温度计 输入 : 显示程序状态(当前分段的当前目标值变化方向)。 Pt100 JPt100 K 热电偶 J 温度输入 E L U 模拟量输入类型 T N R S B W PL II 10~70°C 60~120°C 115~165°C 140~260°C 4~20 mA 0~20 mA 1~5 V 0~5 V 0~10 V 红外温度...
- マニュアル
... to protect level. • Hold the M key and the D key together for at least 1 second to switch Run/Reset. Operation Menu Initial Setting Level Input Type Input type Platinum resistance thermometer Input Pt100 JPt100 Thermocouple ...
- マニュアル
... Down keys • Front-panel Setup Tool port This port is used to connect the Controller to a computer to use the Setup Tool. • Level key Use this key to change levels: Input type Input Setting Pt100 JPt100 Thermocouple ...
- マニュアル
...3 4 5 6 R 铂电阻温度计 输入 :保护指示当设定变更保护为ON(禁用向上、向下键时) 时点亮。 Pt100 JPt100 K 热电偶 J 温度输入 E L U 模拟量输入类型 T N R S B W PL II 10~70°C 60~120°C 115~165°C 140~260°C 4~20 mA 0~20 mA 1~5 V 0~5 V 0~10 V 红外温度传感器...
- マニュアル
...233 M d-d 40 c-db 635HVSRQVH ,QWHJUDO7LPH 8QLW6HFRQGV ol-h 098SSHU/LPLW 100.0 M 635HVSRQVH 'HULYDWLYH7LPH 8QLW6HFRQGV ol-l 0.0 (UURUVKRZQRQO\IRU3URFHVVYDOXH6HWSRLQW1RWVKRZQIRURWKHUVWDWXV Pt100 JPt100 ✣⭫ڬ ...
- マニュアル
...ᰬօ 䭤ૂM䭤㠩ቇ3〈ԛ࠽ᦘ㠩ؓᣚ㨒ঋȾ ᬃ֒㨒ঋ 䗉㊱ޛශ ࡓခ䇴ᇐ㨒ঋ 䗉㊱ޛශ 䫸⭫䱱 ᓜ䇗 䗉ޛ Pt100 JPt100 ✣⭫ڬ K J ᓜ䗉ޛ T E L U 䇴ᇐ㤹പ 䇴ᇐ 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 °C -200Њ850 -199.9Њ500.0 0.0Њ100.0 -199.9Њ500.0 0.0Њ100.0 -200Њ1300 -20.0Њ500....
- マニュアル
...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Pt100 JPt100 ✣⭫ڬ K J ᓜ䗉ޛ T E L U °F -300Њ1500 -199.9Њ900.0 0.0Њ210.0 -199.9Њ900.0 0.0Њ210.0 -300Њ2300 0.0Њ900.0 -100Њ1500 0.0Њ750.0 -300Њ700 -199.9Њ700.0 -300Њ1100 -100Њ1500 -300Њ700 -199.9Њ700.0 -300Њ2300 0Њ3000 0Њ3000 0Њ3200 0Њ3200 0Њ2300 0Њ190 0Њ240 0Њ320 0Њ500 ⁗ᤕ䠅䗉ޛ ㊱ශ N R S B C/W PL II 10Њ70°C 㓘ཌᓜ ՖಞES1B 60Њ120°C 115Њ165°C 140Њ260°C...
- マニュアル
...L H SP X SP X SP X 0 0 X X 0 X 0 X 0 X 0 0 X X 0 ON OFF K SP Vary with "L", "H" values ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF JPt100 SP X Vary with "L", "H" values ON OFF Pt100 X X SP X SP X X X J 0 0 0 X 0 X 0 X X X 0 0 0 X ON OFF X X ON OFF X 0 0 ON OFF Input type Temperature inputs 4...
- マニュアル
... digit max. Platinum resistance thermometer: (±0.1 % of indication value or ±0.5°C, whichever is greater) ±1 digit max. Analog input: ±0.1 % FS ±1 digit max. Event input Output current: approx. 7 mA per contact. Contact input ON:1 ...