PDF1 Product Overview 2 IP Address Setting
...untrusted devices. • Install firewalls to shut down unused communications ports and limit communications hosts and isolate control/monitor systems and equipment from the IT network. • Use a virtual private network (VPN) for remote access to control/monitor systems and equipment. • Scan virus to ensure safety of ...

https://www.fa.omron.co.jp/data_pdf/mnu/t213-e1-07_s8vk-x.pdf

マニュアル
PDF[V061-E1-06] NT-ZJCAT1-EV4 Support Tool for Window...
... etc. 555 Appendix M Connecting Cable Specifications Tool Interface Connector Specifications The following specifications apply to the connection between the PT and the support tool (personal computer). Pin No. Signal Name Meaning 1 FG Frame ground 2 ...

https://www.fa.omron.co.jp/data_pdf/mnu/v061-e1-06_nt-zjcmx1-v4.pdf

マニュアル
PDF[V062-E1-06] NT31-ST123(B)-EV3, NT31C-ST143(B)-EV3...
... for Other Connections (Other Than the Memory Link Method) (page 76). Serial Port A 1 6 NT31/NT31C Abbreviation FG RS-232C interface Pin number Connector hood 5 Pin number Shielding wire SD SD 2 3 RD RD 3 4 RS RS 4 5 CS CS 5 6 - +5V 6 7 5G 7 8 - 8 - - 9 - - (9-pin type) 14 13 25 FG 2 * 1 Abbreviation 1 1 5G 9 PLC (host link unit) - - - ER RS-232C interface (25-pin type) * For Units that have a CTS setting selector switch, RS and CS do not have to be shorted ...

https://www.fa.omron.co.jp/data_pdf/mnu/v062-e1-06_nt31_31c_setup.pdf

マニュアル
PDF[V063-E1-05] NT631-ST211(B)-EV2, NT631C-ST141(B)-E...
... Connections (Other Than the Memory Link Method) (page 75). Serial Port A, B 1 6 NT631/NT631C Abbreviation FG RS-232C interface 5 Shielding wire Pin number Abbreviation 1 FG 1 2 SD SD 2 3 RD RD 3 4 RS RS 4 5 CS CS 5 6 - +5V 6 7 SG 7 8 - 8 - - 9 - - SG 9 Pin number Connector hood PLC (host link unit) (9-pin type) * - - - ER 1 14 13 25 RS-232C interface (25-pin type) * For Units that have a CTS setting selector switch, RS and CS do not have to be shorted if ...

https://www.fa.omron.co.jp/data_pdf/mnu/v063-e1-05_nt631_631c_setup.pdf

マニュアル
PDFProgrammable Terminal NA-series
... Vista, Excel, and Visual Basic are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/v117-e1-14_na5-______.pdf

マニュアル
PDF[V118-E1-25] NA5-15[]101[](-V1)/12[]101[](-V1)/9[]...
... Vista, Excel, and Visual Basic are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/v118-e1-25_na5-______.pdf

マニュアル
PDF[V119-E1-15] NA5-15[]101[](-V1)/12[]101[](-V1)/9[]...
... Vista, Excel, and Visual Basic are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/v119-e1-15_na5-______.pdf

マニュアル
PDF[V120-E1-04] NA5-7[]001[]/9[]001[]/12[]101[]/15[]1...
... Vista, Excel, and Visual Basic are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/v120-e1-04_na5-______.pdf

マニュアル
PDFProgrammable Terminal NA-series
... Vista, Excel, and Visual Basic are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/v125-e1-06_na5-______-v1.pdf

マニュアル
PDF[V228-E1-02] ITNC-EPX01(-DRM) Open Network Control...
... (COM1, COM2, or COM3) of the Open Network Controller to port A of the PT. Open Network Controller 1 2 3 4 SG 5 6 RS 7 CS 8 9 COM1 COM2 COM3 RD SD 3-7 PT 1 2 SD 3 RD 4 RS 5 CS 6 7 8 9 SG PORT A Connecting DeviceNet Cables This section explains how to connect DeviceNet cables to the Open Network Controller. 3-7-1 Connectors Model Specifications Manufacturer MSTB2.5/5-ST5.08AU For node connections. Connector screws not supplied. XW4B-05C1-H1-D For node connection and T-branch ...

https://www.fa.omron.co.jp/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf

マニュアル
PDF[V229-E1-03] CS1W-SPU01/SPU02, CJ1W-SPU01 SPU Unit...
... using the Special Cable. For the UPS setting in the Setup Tool, set the power failure signal as a negative logic input. UPS BU606F BU70XS Applicable Special Cable BUC10 BUC16 Special Cable Wiring (Reference) SPU Cable: BUC10/BUC16 ...

https://www.fa.omron.co.jp/data_pdf/mnu/v229-e1-03_3.pdf

マニュアル
PDF[V421-E1-02] NA5-[]W[][][][]/1[]W[][][][] Programm...
... scripts (Visual Basic). Clears the alarm logs. Closes the specified page. Sets the variable to a specified value. Increases the variable to a specified quantity. Decreases the variable by specifying the quantity. Disables the touch screen. Enables the touch screen. Ejects the ...

https://www.fa.omron.co.jp/data_pdf/mnu/v421-e1-02_na5-_w____.pdf

マニュアル
PDF[V423-E1-02] NA5-[]W[][][][]/1[]W[][][][] Programm...
... Step 2 appear. You can recover from the problem by referring to what is displayed in “Detailed Information”. 4. In Steps 2 and 3, if you press the “Screen Shot” button, the currently displayed screen can be captured and saved in an ...

https://www.fa.omron.co.jp/data_pdf/mnu/v423-e1-02_na5-_w____.pdf

マニュアル
PDF[V461-E1-01] NA5 → NA5-V1 Replacement Guide
...□□□□-V1 (j) (a) (b) (a) (j) (d), (e) (c) (d), (e) (c) (f) (b) (f) (g) (i) (i) (g) (h) (a) Battery cover (b) Expansion unit connector cover*1 (c) SD memory card slot (d) Ethernet port (e) Serial port*1 (f) USB port(host) (g) USB port(slave) (h) Reset switch (i) 24VDC (j) Identification label (h) (a) Battery cover (b) ...

https://www.fa.omron.co.jp/data_pdf/mnu/v461-e1-01_na5_na5-v1_replace.pdf

マニュアル
PDFレーザ製品を安全に使用していただくために 安全上の要点 ■一般仕様
...φ20 37 2-M5×10 取付穴寸法 R18 18 24 ■配線図形V500-R2CF ■性能仕様形式 緑白灰青茶 − 黒赤黄橙 信号名 SD 1 2 RD RS 3 4 CS TRIG 5 6 NC S GND 7 8 VCC −(注) OK −(注) NG 役割 バーコードリーダ 送信パラメ−タ受信パラメ−タ送信要求送信可外部トリガ信号無接続 0V 電源読...

https://www.fa.omron.co.jp/data_pdf/mnu/v500-r2cf_inst-5339935-0h.pdf

マニュアル
PDF[9703302-6L] V640-HAM11-(L)-(ETN)-V□ アンプユニット 取扱説明書...
...~26.4V (九)使用微功率短距离无线电发射设备应当符合国家无线电管理有关规定 10. インド/India 認証番号/Certification number ETA-SD-20230706639 ETA-SD-20230706618 アンプユニット/Amplifier Unit V640-HAM11-V4 V640-HAM11-ETN-V2 5. 韓国/Rebublic of Korea 認証番号/Certification number MSIP-RMM-OMR-V64151 MSIP-RMM-OMR-V64153 MSIP-CMM-OMR-V64152 MSIP-CMM-OMR-V64154 アンプユニ...

https://www.fa.omron.co.jp/data_pdf/mnu/v640-ham11-(l)-(etn)-v__inst-9703302-6l.pdf

マニュアル
PDF[W165-E1-04] C200H-ASC02 ASCII Unit Operation Manu...
...Cable Length: 15 m 9 6 9 6 ····· ···· ····· ···· 5 Port 1 1 5 Port 2 1 Pin No. Symbol Name Direction 1 FG Frame ground – 2 SD Send data Output 3 RD Receive data Input 4 RTS Request to send Output 5 CTS Clear to send Input 6 – Not used – 7 DSR Data send ready Input 8 DTR Data terminal ready Output 9 SG Signal ground – 111 Appendix B Specifications Connections to Peripheral Devices RS-232 Printer Connections ASCII Unit Printer FG 1 1 FG SG 9 7 SG ...

https://www.fa.omron.co.jp/data_pdf/mnu/w165-e1-04_c200h_asc02.pdf

マニュアル
PDF[W174-E1-07] C1000H-SLK11/SLK21-V1, C200HW-SLK13/S...
...SYSMAC C-series SYSMAC LINK C-series SYSMAC LINK System Manual Revised September 2003 SLK11 SLK21-V1 RUN ERC P/S ERH RUN ERC ERH INS M/S INS M/S SD RD SD RD TS LNK TS LNK SLK24 SLK14 RUN ERC INS SD P/S ERH M/S RD TS LNK RUN ERC INS ...

https://www.fa.omron.co.jp/data_pdf/mnu/w174-e1-07_c200hw_slk___c1000h_slk__-v1.pdf

マニュアル
PDF[W266-E1-09] C200HW-SRM21-V1, CJ1W-SRM21, CQM1-SRM...
...-V1 Master Unit for CS-series, C200HX/C200HG/C200HE-(Z)E, and C200HS PLCs Section 4-1 Indicators The following table shows the meaning of the indicators. Indicator RUN (green) Status ON Meaning The Unit is operating normally. OFF ...

https://www.fa.omron.co.jp/data_pdf/mnu/w266-e1-09_c200hw_cj1w_cqm1_srt1_srt2.pdf

マニュアル
PDF[W303-E1-09] C200HX, C200HG, C200HE Programmable C...
... Communications Section 8-2 The connections between the C200HX/HG/HE and a personal computer are illustrated below as an example. C200HX/HG/HE Personal computer Signal Pin No. Pin No. Signal FG 1 1 – SD...

https://www.fa.omron.co.jp/data_pdf/mnu/w303-e1-09_c200hx_hg_he_ope.pdf