全 1073 件が検索されました。(921 - 940件を表示)
- 商品情報
... 110% of rated supply voltage (90% to 110% at 12 to24 VDC) Power consumption Approx. 5.1 VA/Approx. 2.4 W Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1...
- 商品情報
... 110% of rated supply voltage (90% to 110% at 12 to24 VDC) Power consumption Approx. 5.1 VA/Approx. 2.4 W Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1...
- 商品情報
... 240 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 6.2 VA Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 ...
- 商品情報
... 110% of rated supply voltage (90% to 110% at 12 to24 VDC) Power consumption Approx. 5.1 VA/Approx. 2.4 W Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1...
- 商品情報
... 1 min Impulse withstand voltage Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV Noise immunity Between power terminals: ±480 kV Between input terminals: ±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 µ...
- 商品情報
... 240 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 6.2 VA Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 ...
- 商品情報
... 110% of rated supply voltage (90% to 110% at 12 to24 VDC) Power consumption Approx. 5.1 VA/Approx. 2.4 W Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1...
- 商品情報
... 240 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 6.2 VA Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 ...
- 商品情報
... 110% of rated supply voltage (90% to 110% at 12 to24 VDC) Power consumption Approx. 5.1 VA/Approx. 2.4 W Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1...
- 商品情報
... 240 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 6.2 VA Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 ...
- 商品情報
... 110% of rated supply voltage (90% to 110% at 12 to24 VDC) Power consumption Approx. 5.1 VA/Approx. 2.4 W Time ranges(Number of ranges) 10 Time ranges 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1...
- 商品情報
... Hz 1 min Impulse withstand voltage Between power terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV Noise immunity Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
... min Impulse withstand voltage Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV Noise immunity Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
... Hz 1 min Impulse withstand voltage Between power terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV Noise immunity Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
... min Impulse withstand voltage Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV Noise immunity Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
...: 1000 VAC 50/60 Hz 1 min Impulse withstand voltage Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV Noise immunity Between count input terminals: ±500 V Between reset terminals: ±500 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
...: 1000 VAC 50/60 Hz 1 min Impulse withstand voltage Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV Noise immunity Between count input terminals: ±500 V Between reset terminals: ±500 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
... voltage Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV Between count input terminals and reset terminals: 3 kV Noise immunity Between count input terminals: ±1.5 kV Between reset terminals: ±500 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
... voltage Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV Between count input terminals and reset terminals: 3 kV Noise immunity Between count input terminals: ±1.5 kV Between reset terminals: ±500 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...
- 商品情報
...: 1000 VAC 50/60 Hz 1 min Impulse withstand voltage Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV Noise immunity Between count input terminals: ±600 V Between reset terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µ...