ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 9709 件が検索されました。(9221 - 9240件を表示)
商品情報
PDFソリッドステート・タイマ H3CA-8H AC200/220/240
...細情報 Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 200/220/240 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 10 VA/Approx. 1.5 W Time ranges(Number of ranges) 7 Time ranges 0.1 to 99.9 s 1 to 999 s 0.1 to 99.9 min 1 to 999 min 0.1 to 99.9 h 1 to 999 h 10 to 9990 h Input method No-voltage input (open and short-circuit) Output modes A: Power ON delay Control output (...

https://www.fa.omron.co.jp/product/item/H3CA-8H_AC200_220_240/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8H DC110
...Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 110 VDC (Ripple 20% max. (If power supply incorporates a single-phase fullwave rectifier)) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 2 ...

https://www.fa.omron.co.jp/product/item/H3CA-8H_DC110/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8H DC24
....co.jp/product/item/H3CA-8H_DC24/en/ 詳細情報 Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 2 ...

https://www.fa.omron.co.jp/product/item/H3CA-8H_DC24/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8 AC100/110/120
...詳細情報 Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 100/110/120 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 10 VA/Approx. 1 W Time ranges(Number of ranges) 7 Time ranges 0.1 to 99.9 s 1 to 999 s 0.1 to 99.9 min 1 to 999 min 0.1 to 99.9 h 1 to 999 h 10 to 9990 h Input method No-voltage input (open and short-circuit) Output modes A: Power ON delay Control output (...

https://www.fa.omron.co.jp/product/item/H3CA-8_AC100_110_120/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8 AC200/220/240
...詳細情報 Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 200/220/240 VAC (50/60 Hz) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 10 VA/Approx. 1 W Time ranges(Number of ranges) 7 Time ranges 0.1 to 99.9 s 1 to 999 s 0.1 to 99.9 min 1 to 999 min 0.1 to 99.9 h 1 to 999 h 10 to 9990 h Input method No-voltage input (open and short-circuit) Output modes A: Power ON delay Control output (...

https://www.fa.omron.co.jp/product/item/H3CA-8_AC200_220_240/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8 DC100
....co.jp/product/item/H3CA-8_DC100/en/ 詳細情報 Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 100 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 1 ...

https://www.fa.omron.co.jp/product/item/H3CA-8_DC100/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8 DC110
...Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 110 VDC (Ripple 20% max. (If power supply incorporates a single-phase fullwave rectifier)) Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 1 ...

https://www.fa.omron.co.jp/product/item/H3CA-8_DC110/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-8 DC24
....co.jp/product/item/H3CA-8_DC24/en/ 詳細情報 Ratings/Performance 情報更新:2025/11/04 Rated supply voltage 24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption Approx. 1 ...

https://www.fa.omron.co.jp/product/item/H3CA-8_DC24/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-A
... power sources may be used for 24 to 240 VDC.)) Operating voltage range 90 to 110% of rated supply voltage (21.6 to 264 VAC/10.8 to 264 VDC) Power consumption Approx. 0.2 to 4 VA/Approx. 0.2 to 2 W Time ranges(Number of ranges) 7 Time ranges 0.1 to 99.9 s 1 to 999 s 0.1 to 99.9 min 1 to 999 min 0.1 to 99.9 h 1 to 999 h 10 to 9990 h Input method No-voltage input (open and short-circuit) Output modes A: ON ...

https://www.fa.omron.co.jp/product/item/H3CA-A/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CA-FA
... power sources may be used for 24 to 240 VDC.)) Operating voltage range 90 to 110% of rated supply voltage (21.6 to 264 VAC/10.8 to 264 VDC) Power consumption Approx. 0.2 to 4 VA/Approx. 0.2 to 2 W Time ranges(Number of ranges) 7 Time ranges 0.1 to 99.9 s 1 to 999 s 0.1 to 99.9 min 1 to 999 min 0.1 to 99.9 h 1 to 999 h 10 to 9990 h Input method No-voltage input (open and short-circuit) Output modes A: ON ...

https://www.fa.omron.co.jp/product/item/H3CA-FA/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A-301 AC100-240/DC100-125
...Short-circuit (ON) residual voltage: 1 V max. Open circuit impedance: 100 kΩ min. Power consumption Relay ON: Approx. 2 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.3 VA (at 240 VAC 60 Hz) Relay ON: Approx. 1.6 ...

https://www.fa.omron.co.jp/product/item/H3CR-A-301_AC100-240_DC100-125/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A8-301 AC100-240/DC100-125
...full-wave rectifier) Allowable voltage variable range 85% to 110% of rated voltage Power consumption Relay ON: Approx. 2 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.3 VA (at 240 VAC 60 Hz) Relay ON: Approx. 1.6 ...

https://www.fa.omron.co.jp/product/item/H3CR-A8-301_AC100-240_DC100-125/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A8E AC100-240/DC100-125
...full-wave rectifier) Allowable voltage variable range 85% to 110% of rated voltage Power consumption Relay ON: Approx. 2 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 2 VA (at 240 VAC 60 Hz) Relay ON: Approx. 0.9 ...

https://www.fa.omron.co.jp/product/item/H3CR-A8E_AC100-240_DC100-125/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A8E AC/DC24-48
...24 to 48 VAC 50/60 Hz 24 to 48 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier) Allowable voltage variable range 85% to 110% of rated voltage Power consumption Relay ON: Approx. 0.9 ...

https://www.fa.omron.co.jp/product/item/H3CR-A8E_AC_DC24-48/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A8S AC24-48/DC12-48
...12 to 48 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier) Allowable voltage variable range 85 to 110% of rated voltage (90 to 110% at 12 to 48 VDC) Power consumption at output ON: Approx. 0.3 ...

https://www.fa.omron.co.jp/product/item/H3CR-A8S_AC24-48_DC12-48/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A8 AC100-240/DC100-125
...full-wave rectifier) Allowable voltage variable range 85% to 110% of rated voltage Power consumption Relay ON: Approx. 2 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.3 VA (at 240 VAC 60 Hz) Relay ON: Approx. 1.6 ...

https://www.fa.omron.co.jp/product/item/H3CR-A8_AC100-240_DC100-125/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-A8 AC24-48/DC12-48
...12 to 48 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier) Allowable voltage variable range 85 to 110% of rated voltage (90 to 110% at 12 to 48 VDC) Power consumption Relay ON: Approx. 0.8 ...

https://www.fa.omron.co.jp/product/item/H3CR-A8_AC24-48_DC12-48/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-AP AC100-240/DC100-125
... 137.5 VDC Low level: 0 to 10 VAC/0 to 10 VDC Power consumption Relay ON: Approx. 2.5 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.8 VA (at 240 VAC 60 Hz) Relay ON: Approx. 2.2 W (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.7 ...

https://www.fa.omron.co.jp/product/item/H3CR-AP_AC100-240_DC100-125/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-AP AC24-48/DC12-48
... signals Start Input method Voltage input Voltage input High level: 20.4 to 52.8 VAC/10.8 to 52.8 VDC Low level: 0 to 2.4 VAC/0 to 1.2 VDC Power consumption Relay ON: Approx. 0.9 W (at 24 VDC)/Relay OFF: Approx. 0.3 ...

https://www.fa.omron.co.jp/product/item/H3CR-AP_AC24-48_DC12-48/en/pdf/

商品情報
PDFソリッドステート・タイマ H3CR-AS AC24-48/DC12-48
...Start, Reset, Gate Input method No-voltage input No-voltage input Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 1 V max. Open circuit impedance: 100 kΩ min. Power consumption at output ON: Approx. 0.3 ...

https://www.fa.omron.co.jp/product/item/H3CR-AS_AC24-48_DC12-48/en/pdf/

本サイトの全ページから入力キーワードを含むページを検索できます。