ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 57628 件が検索されました。(741 - 760件を表示)
マニュアル
PDF[Z470-E1-01] ZS-HL-N Series Smart Sensors 2D CMOS ...
...-XC_A: within 10 m (including Sensor Head cable. Extension Cable cannot be daisy-chained.) - Extension Cable: ZS-XC_B(R): within 22 m (including Sensor Head. Up to two Extension Cables can be daisy-chained.) - Extension cable for a long distance ZS-XC_ _...

https://www.fa.omron.co.jp/data_pdf/mnu/z470-e1-01_zs-hl-n.pdf

マニュアル
PDF[Z472-E1-01] ZS-HL-N Series Smart Sensors Non-proc...
...The format of non-procedural commands are as follows: Example: A command to acquire a measured value MEASURE command * Each character is output as an ASCII code (except for FLOWDATA response). M E A S U R E O ...

https://www.fa.omron.co.jp/data_pdf/mnu/z472-e1-01_zs-hl-n.pdf

マニュアル
PDFAutofocus Multicode Reader VHV5-F Series
..., lighting, and match string, and to call Quickset functions such as Quick Photometry and Quick Focus that actively set up imaging. Serial Command Syntax 1. All Serial Commands start with an ! followed by the command name. All commands must be followed by a carriage return (...

https://www.fa.omron.co.jp/data_pdf/mnu/z476-e-03_vhv5-f.pdf

マニュアル
PDFAutofocus Multicode Reader VHV5-F Series
... as Start/Stop Specifies the command character used to end a Read Cycle. This character must be different from the Start Character. 3  Example: Serial Trigger Command • Read string: 12345, Format Output: Space, Preamble: None, Postamble: \r\n Transmit: S Response: 12345<...

https://www.fa.omron.co.jp/data_pdf/mnu/z477-e-01_vhv5-f.pdf

マニュアル
PDF[Z481-E1-01] V460-H Series Industrial Handheld DPM...
... in the Watch Tab Page, as shown in the figure on the right. Response Format Read data * The receive data in the figure on the right varies depending 1 2 3 4 5 6 7 8 9 0 A 02 C D E CR LF on your environment. Footer 23 8. Initializing the System 8. Initializing the System This document assumes that each device uses the factory default settings. If you change their settings from the defaults, you may not be able to perform various setting procedures as described. 8.1. Initializing the Controller To initialize the controller, initialize ...

https://www.fa.omron.co.jp/data_pdf/mnu/z481-e1-01_v460-h.pdf

マニュアル
PDF[Z483-E1-01] V460-H Series Industrial Handheld DPM...
... in the Watch Tab Page, as shown in the figure on the right. Response Format Read data * The receive data in the figure on the right varies depending 1 2 3 4 5 6 7 8 9 0 A 02 C D E CR LF on your environment. Footer 25 8. Initializing the System 8. Initializing the System This document assumes that each device uses the factory default settings. If you change their settings from the defaults, you may not be able to perform various setting procedures as described. 8.1. Controller To return the controller to its default ...

https://www.fa.omron.co.jp/data_pdf/mnu/z483-e1-01_v460-h.pdf

マニュアル
PDFZP-series EtherNet/IP™ Communication Unit
...ensures compatibility and efficient communications between different manufacturers and devices. CPU Unit --- A CPU Unit is the central part of a Controller that processes inputs from sensors and actuators, and outputs control signals based on a program. It manages the entire system. ...

https://www.fa.omron.co.jp/data_pdf/mnu/z496-e1-02_zp-eip.pdf

マニュアル
PDFCIDRW SYSTEM V640 SERIES AMPLIFIER UNITS ETHERNET ...
...Host Amplifier Unit A test is preformed for the Amplifier Unit using the data 12345678. Command Test data Command code 1 0 Data 1 1 Data 2 2 3 Data 3 4 5 CR Data 4 6 7 8 0Dh Response If the response test data matches the command, the host device and Amplifier Unit are connected correctly. Test data Response code 0 0 Data 1 1 Data 2 2 3 Data 3 4 V640 SERIES AMPLIFIER UNITS ETHERNET TYPE USER'S MANUAL (Z497) 5 ...

https://www.fa.omron.co.jp/data_pdf/mnu/z497-e1-02_v640-ham11(-l)-etn-v.pdf

マニュアル
PDFZP-series RS-232C Communication Unit
.... 17 Terminology Terminology Term Abbreviation Description CPU Unit --- A CPU Unit is the central part of a Controller that processes inputs from sensors and actuators, and outputs control signals based on a program. It manages the entire system. ...

https://www.fa.omron.co.jp/data_pdf/mnu/z499-e1-01_zp-rsa.pdf

マニュアル
PDFVision Sensor FHV7-AI Series AI Detection Camera
... camera. - OK This is an open communication protocol. Areas for control signals, Command, Response, and inspection data are assigned in the PLC’s I/O memory, and data is exchanged between the PLC and the smart camera by sharing the data via IO data ...

https://www.fa.omron.co.jp/data_pdf/mnu/z507-e1-02_fhv7x-c016-s__-w-01.pdf

マニュアル
PDF[Z924-E1-02] G9SP Series Safety Controller Host Co...
... the header. Normally choose RS-232 or RS-485. Choose format 1/format 4. Set the time-out period. Set value for this example Non-procedural 8bit Even 1bit 9600 Yes Regular/RS232C Form1(without CR,LF) 30(300msec) 2-2 RS-232C Serial Communications Connecting to Mitsubishi Electric PLCs Communications cable The suited cable is different according to the combination of component. Please produce the cable of the following connecting wires when connecting with a Mitsubishi Electric Standard PLC FX series. G9SP-series RS-232C Serial Communications Board Connector D-Sub male 9-pin Mitsubishi Electric FX series...

https://www.fa.omron.co.jp/data_pdf/mnu/z924-e1-02_g9sp.pdf

マニュアル
PDF[9308338-0D] ZG2-WDC□□ スマートセンサ 形ZG2-WDS□□□用センサコントロ...
...いでください。 ・ センサヘッドとセンサコントローラ間のケーブルの延長には、別売りの長距離延長ケーブル形 ZG2-XC□□CR(全長3m、8m、15m、25mを用意しています。 全長には、 センサヘッドのコード部分含まず)を使用します。 延長ケーブルの種類によ...

https://www.fa.omron.co.jp/data_pdf/mnu/zg2-wdc___inst-9308338-0d.pdf

マニュアル
PDF3. Orientation when Installing the Sensor Controll...
... laser beams or electric arc-welding machines) 2. Power Supply and Wiring ・ Reverse connection of power supply is not allowed. Connection to AC power supply is also not allowed. ・ Open-collector outputs should not be short-circuited. ・ Use the Extension Cable ZG2-XC□□...

https://www.fa.omron.co.jp/data_pdf/mnu/zg2-wdc_inst-9309251-6d.pdf

マニュアル
PDF3. Orientation when Installing the Sensor Controll...
... Head and Sensor Controller. The total length differs according to the Extension cable. Extension Cable ZS-XC □A : max. total length 10 m (including Sensors) Extension Cable ZS-XC □B(R) : max. total length 22 m (including Sensors) Extension Cable ZS-XC □...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hldc__-n_inst-5727458-6b.pdf

マニュアル
PDF[7978908-3G] ZS-HLDC□□ スマートセンサ 形ZS-HLD□□□用 センサコントロ...
... Head and Sensor Controller. The total length differs according to the Extension cable. Extension Cable ZS-XC □A : max. total length 10 m (including Sensors) Extension Cable ZS-XC □B(R) : max. total length 22 m (including Sensors) Extension Cable ZS-XC □...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hldc___inst-7978908-3g.pdf

マニュアル
PDF■フェライトコアの装着 使用上の注意 (1)日本 JIS C6802:2014規格で、
... a small amount of alcohol. 5. Compatibility ・ The Sensor Head is compatible with the Sensor Controller, and can be used if purchased separately. 6. Cable extend ・ This product can't be connected to long extension cables for sensor head (Model ZS-XC□□...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hlds10_inst-7978887-7j.pdf

マニュアル
PDF■フェライトコアの装着 使用上の注意 (1)日本 JIS C6802:2014規格で、
...にお求めいただいてもご使用できます。 6. ケーブル延長について・ 本製品は、 センサヘッド長距離延長 (形ZS-XC□□CR、形ZS-XC02D、 形 ZS-XEQに接続) はできません。 (1)日本 JIS C6802:2014規格で、 レーザ製品のクラスに応じて使用者が行わなければならない安全...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hlds2v__inst-3705886-0j.pdf

マニュアル
PDF使用上の注意 (1)日本 JIS C6802:2014規格で、
... with a small amount of alcohol. 5. Compatibility ・ The Sensor Head is compatible with the Sensor Controller, and can be used if purchased separately. 6. Cable extend ・ This product can't be connected to long extension cables for sensor head (Model ZS-XC□□...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hlds5__inst-7979296-3j.pdf

マニュアル
PDF[7979315-3C] ZS-XEQ スマートセンサ デジタルイコライザ 取扱説明書 (日/英語)
...語) 形 ZS-XEQ スマートセンサデジタルイコライザ 取扱説明書 ■定格/性能 2. 配線について・ 本製品は形ZS-XC□□CR、形ZS-XC02D専用品です。 形ZS-XC□□CR、形ZS-XC02Dに接続して使用してください。 ・ 形ZS-XC□□CR、形ZS-XC02D以外に接続すると動作しません。 また、故障の原因...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-xeq_inst-7979315-3c.pdf

マニュアル
PDF使用上の注意 ■各部の名称・機能 ■外形寸法図 30 製品が動作不能、誤動作、 または性能・機器への...
...,600 bps 切換可能 * 通信速度 8 bit データビット長ストップビット長データ区切り表示灯 受信時送信時 1 bit CR または CR+LF を自動認識 CR+LF 固定電源:緑、センサ通信中:緑、センサ通信エラー:赤外部端末通信:緑、外部端末通信エラー:赤 保護回路...

https://www.fa.omron.co.jp/data_pdf/mnu/zx2-sf11_inst-3731763-7d.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。