全 63 件が検索されました。(41 - 60件を表示)

  • カタログ

    ... if the K7L is used at its maximum sensitivity. This is because impurities are mixed with the water when it is leaked and the resistance drops. Pure water Impurities in the air Can the K7L Amplifier be used as a replacement for the ...

  • カタログ

    ...Range 1 ❍···Set value that can be used. Note: These values are possible provided that a completely insulated 3-conductor VCT cable with a thickness of 0.75mm2 and a dielectric strength of 600 V is used. 1 F03-16SFC (2) Connection with ...

  • カタログ

    ...Range 1 ···Set value that can be used. Note: These values are possible provided that a completely insulated 3-conductor VCT cable with a thickness of 0.75mm2 and a dielectric strength of 600 V is used. 1 F03-16SFC (2) Connection with ...

  • カタログ

    ... cable and the Sensing Band. Exceeding these distances may lead to faulty operation. Connect one Sensing Band to each Terminal Block. 2. Not applicable to K7L. Q A Can the K7L Amplifier be used as a replacement for the ...

  • カタログ

    ...粉等の不純物を多く含んでいる場合は、検出できる可能性があります。 実機評価でご確認ください。 漏水検知器形61F-GPN-V50や形61F-WL-CP□-NRA の代替として使用できますか? 使用できます。 ただし、耐サージ性能が違うため、屋外の屋上やポンプ盤...

  • 技術解説/使用上の注意事項

    ...式をご確認の上、以下の表を参照ください。 スイッチ 〔接続する機器〕 ・漏液センサ (形K7Lシリーズ) ・漏液検知器(形61F-GPN-V50) 〔表1〕検知帯の配線距離 (並列接続の場合を含む・配線ケーブル断面積:2mm2の場合) 組み合わせる漏液検出器形式 漏液検出器 漏...

  • 技術解説/使用上の注意事項

    ...コントロー ル 50m 50m (単位:mA) リレ ー IV線 セ ーフティ 漏水検知帯 (形F03-15、-16PE、-16PT) を用いて、漏水検知器(形 61F-GPN-V50)の配線可能な長さについて示します。 漏水検知器の復帰電流値を 0.15mA 以上に設定しております。 従って、漏水検知帯の線間漏れ電流...

  • カタログ

    ...換をお薦めします。 (形F61F-APN用のソケット(形8PFA1)に形61F-AO を使用すると形61F-AOは上下逆になります。 ) 形61F-LS 形61F-GPN-V50 形61F-GP-N8-V50 お問い合わせ ただし、形61F本体ごと交換が必要。 リレーユニットだけの交換はできません(装着で 。 きません) 形 61F-...

  • カタログ

    ...知帯はできるだけ近くに設置し、電源と出力を遠方に引き回すようにしてください。 形式 項目 IV線 0m *1 形61F-GPN-V50 形61F-WLA *2 検知帯最大 200m 10∼150m *1 最大 150m 200∼300m *1 最大 100m 350∼400m *1 最大 50m *1. 2mm2の場合 *2. 形61F-WLAは2016年9月末で生産終了いたしま...

  • カタログ

    ... if the K7L is used at its maximum sensitivity. This is because impurities are mixed with the water when it is leaked and the resistance drops. Pure water Impurities in the air Can the K7L Amplifier be used as a replacement for the ...

  • カタログ

    ... if the K7L is used at its maximum sensitivity. This is because impurities are mixed with the water when it is leaked and the resistance drops. Pure water Impurities in the air Can the K7L Amplifier be used as a replacement for the ...

  • カタログ

    ...Range 1 ···Set value that can be used. Note: These values are possible provided that a completely insulated 3-conductor VCT cable with a thickness of 0.75mm2 and a dielectric strength of 600 V is used. 1 F03-16SFC (2) Connection with ...

  • ..._1_2 機能/仕様一覧セレクション漏液センサ 分類形式項目 商品名称 漏水検知器 形K7L-U□/UD□ 形K7L-AT50□/-AT50D□ 形61F-GPN-V50 長距離配線用 漏液検出器 漏液検出器 漏水検知器 外観 特長 出力形態配線距離動作抵抗値 総和で400mの長距離配線を実現。 漏液...

  • ...漏液/漏水を安定検出。 3機種からお選びください選定方法漏液検出器 漏水検知器 形K7L-AT50□/AT50D□ 形K7L-U□/-UD□ 形61F-GPN-V50 リレー × ○ リレーおよびブザー × × トランジスタ ○ × 動作抵抗値(可変式) 0∼50MΩ、0∼1MΩ 0∼50kΩ 外形寸法(本体のみ) 28.8×12.8×46.0 49.4×38.0×70.0 ソ...

  • ...け、 ねじ端子 ◎ 形PF113A ねじ締め (ねじサイズ:M3.5) 取りつけ共用 1,040 はんだづけ端子 ◎ 形PL11 164 形61F-WLA/ 61F-GPN-V50 形61F-GPNV50 11 DINレール取りつけ、 ねじ端子 ◎ 形PF113A ねじ締め (ねじサイズ:M3.5) 取りつけ共用 1,040 はんだづけ端子 ◎ 形PL11 164 形61F-GPN-BT/ 形61F-GPN-BC BT/-BC 11...

  • ...場フロアで使いたい 半導体 / FPD 製造装置内で使いたい 空調設備、ビル電気室その他で使いたい漏水検出器 形61F-GPN-V50 プッシュイン Plus 端子台タイプが欲しいなら ねじ端子タイプが欲しいなら 長距離配線用 漏液検出器 長距離配線用 漏液...

  • 商品情報

    ...) PL08 PHC-5(別売)耐熱形呼水槽警報装置61F-IP-2214PFAなし *1PL15なし漏水警報器61F-WLA *3 ソケット不要(本体の端子で接続) 漏水検知器61F-GPN-V50 *3PF113APFC-N8(本体付属)PL11PHC-5(別売)多機能商品61F-GP-N14 *361F-GP-N15 *361F-GP-NH3 *361F-G1-2 ソケット不要(本体の端子で接続) 61F-G4N-KYD61F-G3N-NGDDC...

  • 商品情報

    ...FAQ04822 下表を参照ください。(表1)漏液検出器 形K7Lシリーズとの接続(表2)漏水検知器 形61F-GPN-V50、形61F-WLA(*1)との接続(表3)漏水検知帯同士の接続(表4) 漏水検知帯と市販ケーブルの接続 *1漏水警報器 形61F-WLAは2017年3月に生産を終了しました。推...

  • 商品情報

    ...FAQ04825 下表を参照ください。(表1) 漏液検出器 K7Lシリーズとの接続 (表2) 漏水検知器 61F-WL-CP□-NRA、61F-GPN-V50(*1)、61F-WLA(*1)との接続(表3) 漏水検知帯同士の接続*1 61F-GPN-V50、61F-WLAは生産を終了しました。推奨代替品の確認方法はこちらのFAQ をご覧ください。(表...

  • 商品情報

    ...シリーズ センサ断線検出機能なし(表2) 漏液検出器 K7Lシリーズ センサ断線検出機能付(表3) 漏水検知器 61F-WLシリーズ、61F-GPN-V50 *1 漏水警報器 61F-WLAシリーズ *1*1 61F-GPN-V50、61F-WLAは生産終了しました。 ■接続方法について・F03-16PE、F03-16PT、F03-16SF、F03-16SFC につい...