ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 642 件が検索されました。(501 - 520件を表示)
マニュアル
PDF[V202-E1-01] C200PC-ISA03-E/ISA[]3-DRM-E/ISA[]3-SR...
...hood 25-pin connector 9-pin connector Connectors and Cables Use the following connectors and cables or equivalent. Name Model Manufacturer Plug SM2A-0901 OMRON Hood Cable XM2S-0911 OMRON AWG28 5P IFVV-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v202-01_c200pc-isa_3_exp01_pd024.pdf

マニュアル
PDF[V469-E1-04] NS → NA Replace Guide
... types. In this example, change BOOL to Boolean and CHANNEL to Ushort, respectively. Data in AT column are displayed as error because the letter “$” at the top is not allowed by the Na series variable naming rules. If a device is assigned to the system memory $...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v469-e1-04_ns_na_replace.pdf

マニュアル
PDF[W111-E1-10] C200H-CPU01-E/CPU03-E/CPU11-E Program...
... 1999 # 0000 to 9999 or 0000 to FFFF 135 Appendix E Programming Instructions Name Mnemonic Symbol BIT COUNTER (@)BCNT(67) Function Operand Data Areas Counts the number of ON bits in one or more words (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w111-10_c200h-cpu01-e_03-e_11-e.pdf

マニュアル
PDF[W130-E1-05] C200H-CPU01-E/CPU03-E/CPU11-E Program...
...HR 1214 HR 1215 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16-TO-4 ENCODER – DMPX(77) Operand Data Areas SB: First source word Ladder Symbols IR, SR, AR, DM, HR, TC, LR DMPX(77) @DMPX(77) SB SB R R Di Di R: Result word Limitations IR, AR, DM, HR, LR Di: Digit designator IR, AR, DM, HR, TC, LR, # The rightmost two digits of Di must each be between 0 and 3. 155 Section 5-16 Data Conversion All source words must be in the same data area. Description...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w130-e1-05_c200h-cpu01-e_03-e_11-e.pdf

マニュアル
PDF[W140-E1-04] C1000H, C2000H Programmable Controlle...
...HR 1214 HR 1215 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16-TO-4 ENCODER – DMPX(77) Operand Data Areas SB: First source word Ladder Symbols IR, SR, AR, DM, HR, TC, LR DMPX(77) @DMPX(77) SB SB R R Di Di R: Result word Limitations IR, AR, DM, HR, LR Di: Digit designator IR, AR, DM, HR, TC, LR, # The rightmost two digits of Di must each be between 0 and 3. All source words must be in the same data area. Description 152 When the execution condition is ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w140-04_c1000h_c2000h.pdf

マニュアル
PDF[W149-E1-02] C1000HF Programmable Controller Opera...
...0 HR 1215 0 15 1 2 RB+1 : HR 11 6 0 3 4-8-6 Encoder - DMPX(78)<77> DMPX(78) determines the position of the highest ON bit in the specified beginning source channel (SB), encodes it into single-digit hexadecimal data according to the bit number, then transfers the result to the specified digit in the result channel (R). Up to four digits from four consecutive source channels starting with ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w149-02_c1000hf.pdf

マニュアル
PDF[W186-E1-04] C500-ASC04 ASCII Unit Operation Manua...
...f 18 24 CN CAN X X f f f f f 19 25 EM S1 X X f f f f f 1A 26 SB EOF X X f f f f f 1B 27 EC ESC X X f f f f f 1C 28 → S4 f f f f f f f 1D 29 ← S5 f f f f f f f 1E 30 ↑ S6 f f f f f f f 1F 31 ↓ S7 f f f f f f f 00 0 NUL X 01 1 SH SOM 02 03 2 SX EOA 3 EX...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w186-04_c500-asc04.pdf

マニュアル
PDF[W201-E1-02] CV500, CV1000, CV2000, CVM1 CV Suppor...
...S襯S喘S鵬 ㎜脇∂㎜㎜㎜㎜展翅蜘蜘 ㎜18 ㎜ …… … … S砿◆h 創 for SNQI 脇1 Swteh for S櫛1 飽m1 S醜ol潮 forS鴇1 Sb比C紺 「orS嶋1 S縛Q1 →ト s賜1 】 1圃2書目闘■麺一蟹田窟圃7蟹園圃■8日間■曽S眉目翻劃一■C MnemonlcLadderPro9『amming Whenaprogramiscreatedinmnem◎nicform,itiSautomaticallywrittentothe workdisk.1/OnamescannormallybebetWeen2and81ettersinlength,butenly sIettersaredisplayedinthemnemonicprogram.1/OcommentscanbeuptO30 characterslong.AIIl10commentscreatediRthemnemonicdisplaymodecanbe 74・ ---------------------[End of Page 9104]--------------------- P?り即〃∂卿inカ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w201-e1-02_cv500_cv1000_cv2000_cvm1.pdf

マニュアル
PDF[W206-E1-04] CV500-BSC11/BSC21/BSC31/BSC41/BSC51/B...
...FG Frame ground --- Applicable Connector Plug: XM2A-0901 (OMRON) Hood: XM2S-0911 (OMRON) or equivalent One plug and one hood are supplied for each port. Connectors other than those on the left cannot be used. Recommended Cables AWG28 x 5P IFVV-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w206-e1-04_cv500_bsc11_21_31_41_51_61.pdf

マニュアル
PDF[W207-E1-02] CV500-BSC11/BSC21/BSC31/BSC41/BSC51/B...
...130 140 150 160 170 180 190 200 210 220 230 240 250 0k RUN MKI$( MKS$( 'testco㎜andnarne:MK工$/MKS$/MKD$ PARACTO DIMBUF$128 1A宅=100駕:SB=12345.6=DC#=12345.123456789# OPEN"DATA"AS#1 F工ELD#ユ,128ASBUF$ A$=MK工$(IA%) PR工NT"MK工$(":1A毯;")一一〉";A$ B$=MKS$(...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w207-e1-02_cv500-bsc.pdf

マニュアル
PDF[W208-E1-02] C200H-FZ001 Fuzzy Logic Unit Operatio...
...A (F n) FD Label E Label F Label G FF FG SF SG FE FB Fuzzy output n Label D FC FA 0 0 SA SB SC SD SE FFF Output data If all of the fuzzy outputs are zero, the divisor in the equation above will also be zero, the division will not be performed and the Error Flag (bit 15) and No Corresponding Output Flag (bit 04) for that output will be turned ON. Refer to 3-3-2 Output Data for details on the output data format. Maximum Value Method 8 The maximum value method uses ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w208-02_c200h-fz001.pdf

マニュアル
PDF[W216-E1-01] CV500-MP311-E Graphic Programming Con...
...152 SUBROUTINERETURN ROL(↑) 062 ROTATELEFT ROLL(↑) 066 DOUBLEROTATELEFT ROOT(↑) 140 SQUAREiROOT ROR(↑) 063 ROTATERIGHT RORL(↑) 067 DOUBLEROTATERIGHT RSET側) 017 RSET SA(↑) 210 ACTIVA「「ESTEP SBB(↑) 081 BlNARYSUBTRACT ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w216-e1-01_cv500-mp311-e.pdf

マニュアル
PDF[W217-E1-02] C200H-CPU21-E/CPU23-E/CPU31-E Program...
...HR 1215 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5-17-8 16-TO-4 ENCODER – DMPX(77) Operand Data Areas SB: First source word Ladder Symbols IR, SR, AR, DM, HR, TC, LR DMPX(77) @DMPX(77) SB SB R R Di Di R: Result word Limitations IR, AR, DM, HR, LR Di: Digit designator IR, AR, DM, HR, TC, LR, # The rightmost two digits of Di must each be between 0 and 3. All source words must be in the same data area. Description 152 When the execution condition ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w217-02_c200h-cpu21-e_23-e_31-e.pdf

マニュアル
PDF[W235-E1-04] C200HS Programmable Controllers Opera...
... remain in R (counting from the designated first digit), the remaining digits will be placed at digits starting back at the beginning of R. The final word to be converted (S plus the number of digits to be converted) must be in the same data area as ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w235-e1-04_c200hs.pdf

マニュアル
PDF[W304-E1-05] C200HW-COM01/COM02-V1 to C200HW-COM06...
...Output 9 Signal ground SG – Shell Safety ground FG – Plug: XM2A-0901 (OMRON) or equivalent Hood: XM2S-0911 (OMRON) or equivalent Note One plug and one hood are provided. Recommended Cable 12 AWG28 5P IFVV-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w304-e1-05_c200hw_com01_com02_v1-06_v1.pdf

マニュアル
PDF[W351-E1-03] CVM1D-DPL Duplex System Programmable ...
...0 0 0 0 0 0 0 0 0 0 0 0 5-17-9 DATA ENCODER: DMPX(111) Ladder Symbol (111) DMPX Variations j DMPX(111) Description 216 SB Operand Data Areas R SB: 1st source word CIO, G, A, T, C, DM R: Result word CIO, G, A, DM, DR, IR Di: Digit designator CIO, G, A, T, C, #, DM, DR, IR Di When the execution condition is OFF, DMPX(111) is not executed. When the execution condition is ON, DMPX(111) can be used to convert either 16-bit units (2 words) or 256-bit units (32 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w351-e1-03_cvm1d-dpl.pdf

マニュアル
PDF[W365-E1-02] CQM1H-SCB41 Serial Communications Boa...
...-1 (0.7 m) XW2Z-200T-1 (2 m) Applicable Connectors Socket: XM2A-0901 (OMRON) or equivalent Hood: XM2S-0911-E (OMRON, conforms to ESD) or equivalent One Socket and one Hood are provided for each port. Recommended Cables UL2464 AWG28×5P IFS-RVV-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w365-e1-02_cqm1h-scb41.pdf

マニュアル
PDFw384-e1-01_cs1w-hio01_hcp22_hca22.pdf
...X Contents of S (IR 010): $0014 91 Section 2-15 Logic Instructions 2-14-2 BIT COUNTER – BCNT(67) Operand Data Areas Ladder Symbols N: Number of words (BCD) BCNT(67) @BCNT(67) N N SB SB R R IR, SR, AR, DM, EM, TIM/CNT, LR, # ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w384-e1-01_cs1w-hio01_hcp22_hca22.pdf

マニュアル
PDFw433-e1-10_cx-position.pdf
.../CJ-series CPU Unit RS-232C port Recommended cable Plug Hood Hood Provided with CPU Unit as standard accessories. 14 Connecting to a PLC Recommended Cables Section 2-2 Fujikura Ltd. UL2464 AWG28 × 5P IFS-RVV-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w433-e1-10_cx-position.pdf

マニュアル
PDF[W452-E1-08] NSJ5, NSJ8, NSJ10, NSJ12, NSJW NSJ Co...
...Page 152 3. Project Tab Item Project Title Number of Labels Initial Screen Initial Label Alarm/Event Recording Method Data Log Recording Method Operation Log Recording Method Error Log Recording Method System Memory ($...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w452-e1-08_nsj_setup.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。