全 559 件が検索されました。(501 - 520件を表示)
- 商品情報
...コレクタ 印加電圧 DC6V以下 出力電流 4mA以下 残留電圧 0.4V以下 (負荷電流4mA時) 論理 負論理(H=「0」、 L=「1」) 回転方向 CW方向 (シャフト側より右回転)で出力コード増加 最高応答周波数 20kHz 出力立ち上がり、立ち下がり時間 2µs以下 (コード長1m、負荷電...
- 商品情報
... (0.8 ms) Output code Gray code Control output Output type PNP open collector Source current 35 mA max. Residual voltage 0.4 V max. (at source current 35 mA) Logic Positive logic (high = 1, low = 0) Direction of rotation Output code increases for ...
- 商品情報
... (0.8 ms) Output code Gray code Control output Output type PNP open collector Source current 35 mA max. Residual voltage 0.4 V max. (at source current 35 mA) Logic Positive logic (high = 1, low = 0) Direction of rotation Output code increases for ...
- 商品情報
... (0.8 ms) Output code Gray code Control output Output type PNP open collector Source current 35 mA max. Residual voltage 0.4 V max. (at source current 35 mA) Logic Positive logic (high = 1, low = 0) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
...Control output Output type NPN open collector Load power supply voltage 30 V max.DC Sink current 35 mA max. Residual voltage 0.4 V max. (at sink current 35 mA) Logic Negative logic (high = 0, low = 1) Direction of rotation Output code increases for ...
- 商品情報
... code Control output Output type PNP open collector Source current 35 mA max. Residual voltage 0.4 V max. (at source current 35 mA) Logic Positive logic (high = 1, low = 0) Direction of rotation Output code increases for ...
- 商品情報
...プンコレクタ ソース電流 35mA以下 残留電圧 0.4V以下 (ソース電流35mA時) 論理 正論理(H=「1」、 L=「0」) 回転方向 CW方向 (シャフト側より右回転)で出力コード増加 位置決め信号 なし ストローブ信号 なし パリティ信号 なし 最高応答周波数 20kHz 起動トル...
- 商品情報
... code Control output Output type PNP open collector Source current 35 mA max. Residual voltage 0.4 V max. (at source current 35 mA) Logic Positive logic (high = 1, low = 0) Direction of rotation Output code increases for ...