ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む


全文検索:全 800 件が検索されました。(481 - 500件を表示)
マニュアル
PDFIndustrial PC Platform NY-series
... Ethernet connectors are provided below. Item 4-14 Specifications Physical layer 10BASE-T, 100BASE-TX or 1000BASE-T Frame length 1,514 bytes max. Media access method CSMA/CD Modulation Baseband Topology Star Transmission media ...

https://www.fa.omron.co.jp/data_pdf/mnu/w634-e2-04_nye.pdf

マニュアル
PDF[Z316-E1-02] FQ-CR2 Fixed Mount 2D Code Reader Use...
...FQ-WN0@@ Connects the Sensors to external devices such as the Touch Finder, computers, and PLCs. Standard RJ45 Ethernet Cable*1 --- Connects the Switching Hub to the Touch Finder, computers, and PLCs. Use a connector that complies with the FCC RJ45 standard. (...

https://www.fa.omron.co.jp/data_pdf/mnu/z316-e1-02_fq-cr.pdf

マニュアル
PDF[Z329-E1-02] FQ-CR1[][][][][]-M Fixed Mount Multi ...
...-WN0@@ Connects the Sensors to external devices such as the Touch Finder, computers, and PLCs. Standard RJ45 Ethernet Cable*1 --- Connects the Switching Hub to the Touch Finder, computers, and PLCs. Use a connector that complies with the FCC RJ45 standard. (...

https://www.fa.omron.co.jp/data_pdf/mnu/z329-e1-02_fq-cr1_____-m.pdf

マニュアル
PDFRFID System V680S Series Reader/Writer
.../Writers. Installation and Removal • Never use an AC power supply. Doing so may result in rupture. • Wire the Product correctly. Incorrect wiring may result in rupture or burning. • Connect the Ethernet Cable to a host device (e.g., Switching Hub or PLC) that supports ...

https://www.fa.omron.co.jp/data_pdf/mnu/z339-e1-18_v680s-hmd6_-etn.pdf

マニュアル
PDFRFID System V680S Series Reader/Writer
.../Writers. Installation and Removal • Never use an AC power supply. Doing so may result in rupture. • Wire the Product correctly. Incorrect wiring may result in rupture or burning. • Connect the Ethernet Cable to a host device (e.g., Switching Hub or PLC) that supports ...

https://www.fa.omron.co.jp/data_pdf/mnu/z353-e1-16_v680s-hmd6_-eip.pdf

マニュアル
PDFVision Sensor FH Series Vision System
... details. Insert the wiring method into £ in the model number as follows. Phillips screw = J, Slotted screw (rise up) = E, Push-in spring = P Refer to the XW2R (General-purpose devices) Data Sheet for details. Recommended EtherCAT and EtherNet/IP Communications Cables Use Straight ...

https://www.fa.omron.co.jp/data_pdf/mnu/z366-e1-28_fh.pdf

マニュアル
PDFUHF RFID System V780-series Reader/Writer
.... • The cables may break. Confirm cable specifications and do not bend cables past their normal bending radius. • The Reader/Writer may be damaged. Never use an AC power supply. • Connect the Ethernet cable to a host device (e.g., Switching Hub or PLC) that supports ...

https://www.fa.omron.co.jp/data_pdf/mnu/z389-e1-13_v780-hmd68-etn-__-s.pdf

マニュアル
PDF[Z400-E1-09] GI-S[][][][][][] Safety I/O Terminal ...
...3-6 GI-SMD1624 / GI-SID1224 Media access method CSMA/CD Modulation Baseband Transmission path Star, daisy chain, mixed (star and daisy chain), ring (DLR) Transmission rate 100M bit/s (100BASE-TX) Transmission media Twisted-pair cable (shielded: ...

https://www.fa.omron.co.jp/data_pdf/mnu/z400-e1-09_gi-s.pdf

マニュアル
PDFUHF RFID System V780-series Reader/Writer
.... • The cables may break. Confirm cable specifications and do not bend cables past their normal bending radius. • The Reader/Writer may be damaged. Never use an AC power supply. • Connect the Ethernet cable to a host device (e.g., Switching Hub or PLC) that supports ...

https://www.fa.omron.co.jp/data_pdf/mnu/z402-e1-11_v780-hmd68-e__-__.pdf

マニュアル
PDFVision Sensor FHV Series Smart Camera
... not lay the communications cables in locations subject to excessive dirt and dust or to oil mist or other contaminants. Cables 6-36 FHV Series Smart Camera Setup Manual (Z408-E1) 6 Power Supply and I/O Interface • Connect straight LAN cables. • Use ...

https://www.fa.omron.co.jp/data_pdf/mnu/z408-e1-11_fhv7h.pdf

マニュアル
PDF[Z411-E1-02] V330-F/V430-F-series Auto Focus Multi...
...----- Name NJ Series CPU Unit (Built-in EtherNet/IP Port) Power Supply Unit Switching hub Sysmac Studio Sysmac Studio Project File OMRON PC (OS: Windows 10) USB cable (USB 2.0-compliant B-type connector) LAN cable (...

https://www.fa.omron.co.jp/data_pdf/mnu/z411-e1-02_v330-f_v430-f.pdf

マニュアル
PDF[Z412-E1-01] V330-F/V430-F-series Auto Focus Multi...
...1.44 OMRON Sysmac Studio Project File OMRON_V330_V430_NJ_ ETN(TCP)_V100. smc2 Ver. 1.00 --- PC (OS: Windows 10) --- --- USB cable (USB 2.0-compliant B-type connector) --- --- LAN cable (STP (shielded, twisted-pair) cable of Ethernet category 5 or higher) OMRON Code reader V330-F064N12M-NNX Ver. 2.1.0 OMRON PoE (Power over Ethernet) injector Select one that can be powered via Ethernet. --- --- 24 VDC power supply --- 6 5. Applicable Products and Support Tools • Configuration with V430-F PC (Sysmac Studio installed, OS: Windows 10) NJ301-1200 (Built-in EtherNet/IP Port) USB cable Switching...

https://www.fa.omron.co.jp/data_pdf/mnu/z412-e1-01_v330-f_v430-f.pdf

マニュアル
PDF[Z413-E1-01] V330-F/V430-F-series Auto Focus Multi...
...4.□□ OMRON OMRON OMRON OMRON CX-Programmer Network Configurator CX-Programmer Project File (Ladder Program) Network Configurator Project File OMRON PC (OS: Windows 10) USB cable (USB 2.0-compliant B-type connector) LAN cable (...

https://www.fa.omron.co.jp/data_pdf/mnu/z413-e1-01_v330-f_v430-f.pdf

マニュアル
PDF[Z420-E1-02] V330-F/V430-F-series Auto Focus Multi...
...OMRON OMRON OMRON OMRON OMRON ----OMRON OMRON --- Name NX Series CPU Unit (Built-in EtherNet/IP Port) Power Supply Unit Switching hub Sysmac Studio Sysmac Studio Project File PC (OS: Windows 10) LAN cable (...

https://www.fa.omron.co.jp/data_pdf/mnu/z420-e1-02_v330-f_v430-f.pdf

マニュアル
PDF[Z429-E1-01] V330-F/V430-F-series Auto Focus Multi...
...NJ-PA3001 W4S1-05C SYSMAC-SE2□□□ OMRON_V330_V430_NX_ ETN(TCP)_V100.csm2 --- Ver. 1.28 Ver. 1.00 V330-F064N12M-NNX Ver. 2.1.0 --- OMRON PC (OS: Windows 10) LAN cable (STP (shielded, twisted-pair) cable of Ethernet category 5 or higher) Code reader OMRON Power over Ethernet (PoE) single Select one that can be --- port injector 24 VDC power supply powered via Ethernet. --- 8 5. Applicable Products and Support Tools • Configuration with V430-F PC (Sysmac Studio installed, OS: Windows 10) NX1P2-9024DT (Built-in EtherNet/IP Port) Ethernet cable V430-WE-3M LAN cable 24 ...

https://www.fa.omron.co.jp/data_pdf/mnu/z429-e1-01_v330-f_v430-f.pdf

マニュアル
PDF[Z431-E1-01] V330-F/V430-F Series Auto Focus Multi...
.... 9.72 Ver. 2.03 Ver. 1.00 --- --- OMRON CX-Programmer CX-Protocol CX-Protocol Project File (Ladder Program) PC (OS: Windows 10) USB cable (USB 2.0-compliant B-type connector) LAN cable (STP (shielded, twistedpair) cable of Ethernet category 5 or higher) Code reader V330-F064N12M-NNX Ver. 2.1.0 OMRON PoE (Power over Ethernet) injector Select one that can be --- ------- Ver. 1.00 ----- powered via Ethernet. 9 5. Applicable Products and Support Tools ・ Configuration with V430-F PC (OS: Windows 10, CX-One Installed) CJ2M-CPU11 CJ1W-ETN21 USB cable V430-F000M12M-SRX Switching hub (...

https://www.fa.omron.co.jp/data_pdf/mnu/z431-e1-01_v330-f_v430-f.pdf

マニュアル
PDF[Z436-E1-05] FH-505[]/SMDA-GS050B Vision System Ha...
... number as follows. 0.5 m = 050, 1 m = 100, 1.5 m = 150, 2 m = 200, 3 m = 300, 5 m = 500 Refer to the XW2K Series Datasheet (Cat. No. G152) for details. Recommended EtherCAT and EtherNet/IP Communications Cables Use Straight ...

https://www.fa.omron.co.jp/data_pdf/mnu/z436-e1-05_fh.pdf

マニュアル
PDF[Z441-E-01] F430-F Series Smart camera NX Series E...
...LAN cable DC24V Manufacturer OMRON OMRON OMRON OMRON Name NX Series CPU Unit (Built-in EtherNet/IP Port) Switching hub Sysmac Studio Sysmac Studio Project File OMRON Computer (OS: Windows 10) LAN cable (...

https://www.fa.omron.co.jp/data_pdf/mnu/z441-e-01_f430-f.pdf

マニュアル
PDF[Z443-E-01] F430-F Series Smart camera NX Series G...
...W4S1-05C Ethernet cable V430-WE-3M LAN cable DC24V Manufactur er OMRON OMRON OMRON OMRON OMRON OMRON OMRON - Name DC24V NX1P2-9024DT Computer (OS: Windows 10) LAN cable (STP (shielded, twisted-pair) cable of Ethernet category 5 or higher) Smart camera supply I/O cable V430-W8-3M Model NX Series CPU Unit (Built-in EtherNet/IP Port) Switching hub Sysmac Studio Sysmac Studio Project File I/O cable Ethernet cable DC24V Power camera) F430-F000M12M-SWA (Smart W4S1-05C SYSMAC-SE2□□□ OMRON_F430_NX_EIP_ V100.csm2 F430-F000M12M-SWA V430-W8-3M V430-WE-3M - Version Ver....

https://www.fa.omron.co.jp/data_pdf/mnu/z443-e-01_f430-f.pdf

マニュアル
PDFZP-series EtherNet/IP™ Communication Unit
...-4-4 Connected Devices This section describes the connected devices for wiring the Communication Unit. EtherNet/IP Cables l Connection Cables between Communication Unit and EtherNet/IP Scanner with RJ45 Connectors When you use 100BASE-TX/100BASE-T, use a Category 5 or higher ...

https://www.fa.omron.co.jp/data_pdf/mnu/z496-e1-02_zp-eip.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。