全 55196 件が検索されました。(4961 - 4980件を表示)
- カタログ
... (EN60947-5-1) Mechanical 15,000,000 operations min. *5 Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) Operating speed 1 to 500 mm/...
- カタログ
...0.55 0.55 0.27 0.27 1,000,000 operations min. Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) 2 to 360°/s Operating frequency 30 operations/minute max. Direct opening force *4 1 N·m min. Direct opening travel *4 18° min. Contact resistance 25 mΩ max. Minimum applicable load *5 1 mA resistive load at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V Rated frequency 50/60 Hz Protection against electric shock Class II (double insulation)...
- カタログ
... lock/mechanical release 5. Indicator B: 10 to 115 VAC/VDC (orange LED indicator) 6. Release Key Type Blank: Standard (resin) 4: Special release key (resin) (Note: Release tool is included.) 7. Release Key Position Blank: Bottom ...
- カタログ
...-SJ * M20 D4NS-4AF-SJ * G1/2 D4NS-2BF-SJ * M20 D4NS-4BF-SJ * G1/2 D4NS-2CF-SJ * M20 D4NS-4CF-SJ * G1/2 D4NS-2DF-SJ * M20 D4NS-4DF-SJ * * Models with Korean S-mark certification. 2 D4NS/D4NS-SK Operation Keys Type Model Horizontal mounting D4DS-K1 Vertical mounting D4DS-K2 Adjustable mounting (Horizontal) D4DS-K3 Adjustable mounting (Horizontal/Vertical) D4DS-K5 Slide Keys Appearance Specifications Contents Model Applicable Door Switch Weight: 422 g Slide Key (Operation Key included.): 1 Mechanical durability: Auxiliary mounting bracket: 1 20,000 operations min. Receptacle bracket: 1 D4NS-SK01 D4NS...
- カタログ
... 30mA(抵抗負荷) 動作回数 ︵ × ■性能保護構造 IP67 機械的電気的 500万回以上 (DC30V 30mA 抵抗負荷) 機械的 5∼500mm/s 120回/min 電気的 60回/min 許容操作速度許容操作ひん度 5,000 1,000万回以上 4 回︶ 耐久性 *1 10 3,000 DC30V 1,000 700 絶縁抵抗 各端子と非充電金属部...
- カタログ
...±0.05V 感度 25mV/°±3% 出力電圧のレシオ性*2 温度依存性 100mV/°±3% ±10mV/10℃以下 感度 ±1.5%/10℃以下 ±20mV/10℃以下 1%F.S.以下 応答時間 (90%到達時間) 1s以下 2.5s以下 (+60°→0°ステップ移動)(+15° →0° ステップ移動) 非検出軸の感度 *3 ±50mV以下 振動印加時の出力変動 *4 ±50mV以...
- カタログ
...リーズカタログ MEMSフローセンサ(流量/風速) 形 D6F シリーズシリーズカタログ より高 精 度 に、より高 速 に M E M Sフロー セン サは 、質 量 流 量 計 測 の 理 想に近 づきました 蝶はばたき のさえも フローセンサ オムロンの 検知する なら 蝶の羽ば...
- カタログ
... サ出 力 温 度 [ ℃ ] 28.0 27.0 安定した出力 26.0 25.0 24.0 23.0 22.0 0 5 10 15 20 25 30 時間 [s] 一般相当品 セン サ出 力 温 度 [ ℃ ] 28.0 27.0 出力ばらつき 26.0 25.0 24.0 23.0 22.0 0 5 10 15 20 25 30 時間 [...
- カタログ
...10 to 150 Hz, 0.35-mm single amplitude or 50 m/s2 294 m/s2 150 m/s2 D7F-S01-@@ D7F-S03-05 Analog DC SPDT (30 VDC, 3 A or 250 VAC, 3 A resistive load) ON delay: 0.1 s min. in Continuous Vibration Relay Detection Mode output 5 ms in Intermittent Vibration Detection Mode OFF delay: 1s Transistor Output ±4 VAC (output impedance: 10 kΩ) The output voltages for each range are shown below. AC AC monitor ×1 range, 5.1 mV (m/s2) (typical) monitor ×3 ranges, 15.3 mV (m/s2) (typical) *1 *1...
- カタログ
...- range Torque error → Me Mechanical deterioration Deterioration of the servomotor and mechanical errors rors reduce or increase the torque. Deterioration and other errors are detected by monitoring the torque and comparing it with the normal torque. 3 Point 1 The Omron'...
- カタログ
...: 1 Gbps Port 2: 100 Mbps 1000BASE-T·100BASE-TX (IEEE 802.3) 1,514 bytes max. CSMA/CD 100 m Transmission media Twisted-pair cable of category 5, 5e, or higher (shielded cable) Communications protocol TCP/IP, UDP/IP, HTTP(...
- カタログ
...ON Stability indicator OFF (green) Indicators Indicators Control output (NO) Red Red Green Open circuit Open circuit eliminated Open circuit Time ON Control output OFF (NO) 0.3 s min. ON Self-diagnostic * OFF output Detection indicator ON OFF (red) Stability indicator ON Green (green) OFF 0.3 ...
- カタログ
...E2CY-C2AF 30 35 E2CY-V3A 15 25 7 READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’...
- カタログ
...15 25 7 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’...
- カタログ
... 2 V max. (Load current: 100 mA, Cable length: 2 m) In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability indicator (green, lit) Indicators *1 In the IO-Link mode: Operation indicator (orange, lit) and communication indicator (green, blinking at 1 ...
- カタログ
...M4 Connector model 12 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’...
- カタログ
...Classification Case material and shape Size C Shielding D Sensing distance E Connecting method F G H Output specifications Operation mode Cable specifications Code Cable length Meaning C Cylindrical S SUS, threaded 03 Outer diameter 3 mm 04 Outer diameter 4 mm 05 Threaded: Outer diameter 5 mm, Cylindrical: Outer diameter 5.4 mm 06 Outer diameter 6.5 mm ...
- カタログ
... proximity sensor, making it easy to check the detection status. Previous models The indicator is invisible depending on the orientation of the installed sensor. E2E N EX T When the sensor is installed in the The high-brightness LED indicator is v i ...
- カタログ
... sensing distance, and differences between Before correction individual sensors will be bigger. E2E NEXT Proximity Sensors (3-wire models) solve these issues by newly implementing Thermal Distance Control 2, a technology to enable extended sensing ranges. It enables in-line measurements of each sensor’...
- カタログ
... voltage range is also the same.) *3 Leakage current 0.8 mA max. Control output 10% max. of sensing distance 0.8 kHz 0.5 kHz Load current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models Residual voltage *4 3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) 0.4 kHz Indicators D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) Operation mode (with sensing object approaching) D1 Models: NO D2 Models: NC Diagnostic output delay 0.3 to 1 ...