全 6012 件が検索されました。(3921 - 3940件を表示)
- マニュアル
.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 K Option List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 viii About this Manual: This manual describes connecting the NT-series NT31 and NT31C Programmable Terminals to a PLC (Programmable Controller) or other host and peripheral devices and the settings required for communications and applications. It includes the sections described below. Please read this manual carefully and be sure you understand the information provided before attempting to install and operate the Programmable Terminal. Section 1 provides fundamental information about the functions and features of the PTs, types of connection, communications methods, etc. This information will enable you to understand ...
- マニュアル
.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 K Option List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295 viii About this Manual: This manual describes connecting the NT-series NT631 and NT631C Programmable Terminals (PTs) to a PLC (Programmable Controller) or other host and peripheral devices, and the settings required for communications and applications. It includes the sections described below. Please read this manual carefully and be sure you understand the information provided before attempting to install and operate the Programmable Terminal. Section 1 provides fundamental information about the functions and features of the PTs, types of connection, communications methods, etc. This information will enable you to ...
- マニュアル
... (common use) NT31/NT31C system program data NT-ZS3AT-EV1 (including system installer) The system installer and system program data are supplied with the Support Tool. High-speed 1:N NT Link Not possible Possible1 Memory y Li ...
- マニュアル
... lines to the proper length for the crimp terminal connectors. Twist together the wires of each of the signal and power lines. Strip to match the crimp terminals Note We recommend the following crimp terminals for easier wiring and improved reliability. Phoenix Contact ...
- マニュアル
...-ST143-EV3.) NT31/NT31C system program data NT-ZS3AT-EV1 (including system installer) The system installer and system program data are supplied with the Support Tool. High-speed 1:N NT Link Not possible Possible Memory y Li ...
- マニュアル
... Low selection in the backlight brightness settings (High, Medium, and Low) under the operating settings for NS-series PTs. Brightness can be adjusted externally only with the NS15. Item Recommended resistance range Recommended resistive load power Recommended cable Specification 0 ...
- マニュアル
...H I J G L CN3 3 EF No.5 No.10 CN CN2 No.1 No.6 35 70 +50 10,000 +300 −300 35 100 +10 0 K CN4 15 Section 1-3 Special Cable Specifications No. Product name Pressure-welded socket Socket crimp terminal Housing Contact Crimp socket Socket crimp terminal Heat-shrinkable tube Packing Housing (black) Cable A B C D E F G H I J Model DF3-3S-2R26(01) Maker HRS Quantity 1 DF3-2428SCC HRS 3 SHDR-10V-S-B-LF-SN SSH-003GA-P0.2-LF-SN DF11-18DS-2C DF11-...
- マニュアル
...216 [ESC] X [ESC] B Request Screen Number. Write Character-string Memory Table. 216 218 [ESC] C [ESC] D 4-digit Write Numeral Memory Table 8-digit Write Numeral Memory Table 219 219 [ESC] / [ESC] K Copy Memory Table. Lamp and Touch Switch Display (Bit Specification) 220 223 [ESC] Q Lamp and Touch Switch Display (Number Specification) 223 [ESC] R [ESC] U Lamp and Touch Switch Display Status Enquiry Touch Switch Disable. 224 227 [ESC] V [ESC] P Touch Switch Enable. Screen Display Control 227 227 [ESC] T [ESC] W Buzzer Control System Menu Display Permission 228 228 [ESC] Y [...
- マニュアル
.... . . . . . 54 SECTION 6 Connecting to LG PLCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 6-1 MASKER-K (Cnet) Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 SECTION 7 Connecting to Yokogawa PLCs . . . . . . . . . . . . . . . . . . . . . . . 61 7-1 FA-M3 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 vii TABLE OF CONTENTS SECTION 8 Connecting to Keyence PLCs. . . . . . . . . . . . . . . . . . . . . . . . . 65 8-1 KV-10/16/24/40 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 8-2 KV-700 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 8-3 Connecting through a KV-L20R/V (KV-700-series Unit). . . . . . . . . . . . . . . . . . . . . . . . . . . 70 8-4 KV-1000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 8-5 Connecting through a KV-L20R/V (KV-1000-series Unit). . . . . . . . . . . . . . . . . . . . . . . . . . 74 8-6 KV-3000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 8-7 Connecting through a KV-L20R/...
- マニュアル
... provides a list of Boards that are currently available. 1-2-1 SYSMAC Boards SYSMAC Board C200PC-ISA03-E Equivalent CPU Unit C200HG-CPU43-E Max. No. of Expansion Racks Built-in EEPROM 2 16 K d words C200PC-ISA03-DRM-E C200PC-ISA03-SRM-E C200PC-ISA13-DRM-E C200HX-CPU64-E C200PC-ISA13-SRM-E 3 32 ...
- マニュアル
...settings 2. RESOURCE SETUP COM p port tti settings 3. FinsGateway y SETUP FinsGateway settings 4. ETN SETUP Ethernet NP settings i 5. CLK SETUP Controller Li k NP Link settings 6. SYSMAC SETUP SYSMAC B d NP Board settings Menu item 1. 2. 3. 4. 5. 1. 2. 3. 4. 5. 1. 2. 3. 4. 5. 6 7 1. 2. HostName SubnetMask IpRoute Host File exit COM PROCESS COUNT COM1 PROCESS COM2 PROCESS COM3 PROCESS exit StartService UnitID LocalNetworkTable RelayNetworkTable MemoryAliases_DM MemoryAliases_CIO exit NodeID IpTable 3. 1. 2. 3. 4. 5. 1. 2. 3. exit NodeID BaseAddress...
- マニュアル
..., or the FINS address, according to the DIP switch settings. The 7-segment display shows alphanumeric characters. The alphabet characters that are displayed are shown below. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z DeviceNet Indicators ↑ NS 48 ↑ MS Section 3-2 DIP Switch Settings Indicator Color MS --- NS Status Not lit No power supply. Green Lit Flashing Normal. Starting. Red Flashing Lit Fatal error. Replace the Board. Fatal error. Replace the Board. --Green Not lit Lit Offline. Normal communications. Red...
- マニュアル
...-TX Ethernet. Connecting the Power Failure Signal CS1W-SPU01/SPU02 Connect the power failure signal output line from a UPS or other device to the power failure input terminals on the SYSMAC SPU Unit. Signals Input indicator IN COM 2 ...
- マニュアル
... the Journal folder, which is a Windows network-shared folder. Data collection (sampling) may not be possible if these folders or files are deleted. If any of these folder or files is deleted, perform the procedure to set data collection (sampling) from the SPU-Console. ...
- マニュアル
...設置してください。 容 F ITFの詳細設定 G STFの詳細設定 H NW7の設定 I CODE39の設定 J CODE93の設定 K CODE128の設定 L EAN128の設定 3) 設定内容読み出しコマンド R ■ 接続 (1)コネクタのピン配列 コマンド正常受付時、BCRからのレスポンス(設定内容)はACKに続...
- マニュアル
...源が点灯しブザーも鳴動しつづけます) EAN128ラベル CODE128ラベル [F1]ABCD[F1]E A[F1]BCD[F1]E ABCDE ABCD[F1]E "W"ABCD[GS]E "W"ABCD[GS]E "K"ABCDE "K"ABCD[GS]E "K"ABCDE "K"ABCD[GS]E 不読不読不読 "W"ABCD[GS]E "W"ABCD[GS]E 不読 内 容 バーコード "...
- マニュアル
...-8 STF (2 of 5 5bar) ID A C A B H バーコード体系 ITF NW-7 CODE39 ID I N M CODE93 CODE128 L K EAN128 W 桁数 : バーコードデータの桁数を2バイトで示します。 但し、UPC、EANコードの場合は省略されます。 {N1:10の位 (0∼9) 、N2:1の位 (0∼9)} ■外形図 ■接続 ●バーコードリーダ (65mm...
- マニュアル
...Thefollowingisadescriptionoftheoperationsrequiredtoreadthe contentsofanydesiredaddressiRthepositioncontrolunit'smemory. Timingchart Thisisareferencetimingchanforreadinguserdata.Thetimesindicated bysuchexpressionsas"1scanclock",etc.,areforreferenceonlyand willvaryinactualapPlication. Userdata (PC→POsitioncOntrolunit} Programdatareadrelay (PC→positibncontrolunio ACK (positioncontrolunit→PC) Programdatatransmitrelay (pesitioncontrolunit→PC) Readdata (POsitioncOntrOlunit→PC) D。 t。 ,t,d』rlsca・cb・...
- マニュアル
....2 A min (1.6 A typical) Residual Voltage ON Response Time 0.8 V max. 0.1 ms max. Power for External Supply 35 mA 24 VDC +10%/–15% min. Alarm Output (See note) No. of outputs: 1 (2 kΩ internal resistor) Connectable Units: Only the following DC Input Units and alarm output LED indicators can be connected: C200H-ID001, ID211, ID212, IM211 (DC), IM212 (DC), ID215, ID501, MD115, MD215, MD501 Weight Dimensions 400 g max. B-shape OFF Response Time 0.3 ms max. Internal Circuit Output LED indicator Short-circuit protection circuit Circuit Configuration to 0V...
- マニュアル
...+ B0 B1 B2 + Output – ––– + Output – Sensor 1 Sensor 2 When connecting outputs to logic external circuits, the external circuits must be designed to be compatible with the output specifications of the Output Terminal (pull-up resistance: 4.3 ...